| 数据搜索系统,热门电子元器件搜索 |
|
MHV283R3S/883 数据表(PDF) 11 Page - Interpoint Corporation Company |
|
|
|||||||||||||||||||||||||||||
MHV283R3S/883 数据表(HTML) 11 Page - Interpoint Corporation Company |
|
11 / 21 page ![]() TRIPLE OuTPuT MODEL – MHV28512T 5 (MAIn) ±12 (AuXILIARIES) PARAMETER COnDITIOnS MIn TyP MAX MIn TyP MAX unITS OuTPuT VOLTAGE MAIn AnD POS. AuX 4.90 5.00 5.10 11.76 12.00 12.24 V nEG. AuX. -11.70 -12.00 -12.30 OuTPuT CuRREnT 2 0 — 2.0 0 ±0.208 0.333 1 A VIn=16to50V MAX TOTAL AuX — — — — — 0.416 OuTPuT POWER 3 0 — 10 0 ±2.50 4.00 1 W VIn=16to50V MAX TOTAL AuX — — — — — 5 OuTPuT RIPPLE TC =25°C — 8 20 — 9 20 ±VOuT, 10 kHZ - 2 MHZ TC=-55°Cto+125°C — — 22 — — 22 mV p-p LInE REGuLATIOn MAIn AnD POS. AuX — 0 5 — 5 35 mV VIn =16,50V nEG. AuX. — 7 40 LOAD REGuLATIOn 4 MAIn AnD POS. AuX — 10 20 — 10 30 nEG. AuX. — — — — 40 70 mV CROSS REGuLATIOn 5 EFFECT On — — — — 400 800 mV nEGATIVE AuXILIARy InPuT VOLTAGE COnTInuOuS 16 28 50 — — — V TRAnSIEnT 120 ms 1 — — 80 — — — V InPuT CuRREnT nO LOAD — 30 37 — — — mA InHIBITED — 8.4 10 — — — InPuT RIPPLE CuRREnT 10 kHz - 10 MHz — 10 30 — — — mA p-p EFFICIEnCy TC=25°C 75 78 — — — — TC=-55°Cto+125°C 74 — — — — — % LOAD FAuLT 6 POWER DISSIPATIOn — — 9.5 — — 9.5 W RECOVERy 1 — — 25 — — 25 ms STEP LOAD RESPOnSE 7 TRAnSIEnT — — ±350 — — ±600 mV pk RECOVERy — — 3 — — 4 ms STEP LInE RESPOnSE 1, 8 TRAnSIEnT — — ±400 — — ±500 mV pk 16 - 50 - 16 VIn RECOVERy — — 3 — — 4 ms START-uP 9 DELAy — 7 15 — 7 15 ms OVERSHOOT 1 — — 100 — — 240 mV pk CAPACITIVE LOAD 1,10 25°C — — 200 — — 100 µF table 11: eleCtriCal CharaCteristiCs -55°C to +125°C Case, 28 vin, 100% loaD, Free run, unless otherwise sPeCiFieD. notes 1. Guaranteed by design and/or analysis. not an in-line test. 2. The sum of the 12 volt auxiliary output currents may not exceed 416 mA. 3. The sum of the auxiliary output power may not exceed 5 watts. up to 80% of the total power (5W) is available from either auxiliary providing the opposite auxiliary is carrying 20% of the total auxiliary power used. 4. Load regulation for the +5 is specified at 0.0 to 2.0 A with the aux. both held at 2.5 W (208 mA). Load regulation for the auxiliary is specified as both auxiliaries from 0.0 to 2.5 W (208 mA) at the same time with the +5 held at 2.0 A. 5. Cross regulation occurs between the two auxiliaries and is measured on –aux. +5 is held constant at 2.0 A. Cross regulation is specified for two conditions: 5.A.Positiveaux.=2.5W(50%);negativeaux.=2.5Wto0.5W(50%to10%). 5.B.From+Po=70%and-Po=30%to+Po=30%and-Po=70%. Above conditions are referenced to 50%/50% balanced loads. 6.Loadfaultisashortcircuit(<50mΩ).Recoveryisintoaresistiveload. 7.Steploadtransition≥10µs.Recovery=timetosettletowithin1%ofVOuT final value. negative auxiliary is guaranteed by design and/or analysis. 8.Steplinetransition≥10µs.Recovery=timetosettletowithin1%ofVOuT final value. 9. At inputs above 40 volts with temperatures above approximately 100°C, to ensure start-up, transition time should be greater than 5 ms and use of the inhibit function should be avoided. 10. Applicable to each output. no effect on dc performance. Crane Aerospace & Electronics Power Solutions www.craneae.com/interpoint Page 11 of 21 MHV Rev AC - 2015.01.23 mHV single, dual and triple dc-dc converters 28 Volt input – 15 Watt |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |