13 / 19 page ![]() Application Information EXPOSED-DAP MOUNTING CONSIDERATIONS The LM4849’s exposed-DAP (die attach paddle) package (MH) provides a low thermal resistance between the die and the PCB to which the part is mounted and soldered. This allows rapid heat transfer from the die to the surrounding PCB copper traces, ground plane and, finally, surrounding air. The result is a low voltage audio power amplifier that produces 2.1W at ≤ 1% THD with a 4Ω load. This high power is achieved through careful consideration of necessary ther- mal design. Failing to optimize thermal design may compro- mise the LM4849’s high power performance and activate unwanted, though necessary, thermal shutdown protection. The MH package must have its exposed DAP soldered to a grounded copper pad on the PCB. The DAP’s PCB copper pad is connected to a large plane of continuous unbroken copper. This plane forms a thermal mass and heat sink and radiation area. Place the heat sink area on either outside plane in the case of a two-sided PCB, or on an inner layer of a board with more than two layers. Connect the DAP copper pad to the inner layer or backside copper heat sink area with 32(4x8) (MH) vias. The via diameter should be 0.012in–0.013in with a 1.27mm pitch. Ensure efficient ther- mal conductivity by plating-through and solder-filling the vias. Best thermal performance is achieved with the largest prac- tical copper heat sink area. If the heatsink and amplifier share the same PCB layer, a nominal 2.5in 2 (min) area is necessary for 5V operation with a 4 Ω load. Heatsink areas not placed on the same PCB layer as the LM4849 should be 5in 2 (min) for the same supply voltage and load resistance. The last two area recommendations apply for 25˚C ambient temperature. Increase the area to compensate for ambient temperatures above 25˚C. In systems using cooling fans, the LM4849MH can take advantage of forced air cooling. With an air flow rate of 450 linear-feet per minute and a 2.5in 2 exposed copper or 5.0in 2 inner layer copper plane heatsink, the LM4849MH can continuously drive a 3 Ω load to full power. The LM4849’s power de-rating curve in the Typical Performance Characteristics shows the maximum power dissipation versus temperature. Example PCB layouts for the exposed-DAP TSSOP package is shown in the Demon- stration Board Layout section. PCB LAYOUT AND SUPPLY REGULATION CONSIDERATIONS FOR DRIVING 3 Ω AND 4Ω LOADS Power dissipated by a load is a function of the voltage swing across the load and the load’s impedance. As load imped- ance decreases, load dissipation becomes increasingly de- pendent on the interconnect (PCB trace and wire) resistance between the amplifier output pins and the load’s connec- tions. Residual trace resistance causes a voltage drop, which results in power dissipated in the trace and not in the load as desired. For example, 0.1 Ω trace resistance reduces the output power dissipated by a 4 Ω load from 2.1W to 2.0W. This problem of decreased load dissipation is exacerbated as load impedance decreases. Therefore, to maintain the highest load dissipation and widest output voltage swing, PCB traces that connect the output pins to a load must be as wide as possible. Poor power supply regulation adversely affects maximum output power. A poorly regulated supply’s output voltage decreases with increasing load current. Reduced supply voltage causes decreased headroom, output signal clipping, and reduced output power. Even with tightly regulated sup- plies, trace resistance creates the same effects as poor supply regulation. Therefore, making the power supply traces as wide as possible helps maintain full output voltage swing. BRIDGE CONFIGURATION EXPLANATION As shown in Figure 1, the LM4849 output stage consists of two pairs of operational amplifiers, forming a two-channel (channel A and channel B) stereo amplifier. (Though the following discusses channel A, it applies equally to channel B.) Figure 1 shows that the first amplifier’s negative (-) output serves as the second amplifier’s input. This results in both amplifiers producing signals identical in magnitude, but 180˚ out of phase. Taking advantage of this phase difference, a load is placed between −OUTA and +OUTA and driven dif- ferentially (commonly referred to as “bridge mode”). This results in a differential gain of A VD =2*(Rf/R i) (1) Bridge mode amplifiers are different from single-ended am- plifiers that drive loads connected between a single amplifi- er’s output and ground. For a given supply voltage, bridge mode has a distinct advantage over the single-ended con- figuration: its differential output doubles the voltage swing across the load. This produces four times the output power when compared to a single-ended amplifier under the same conditions. This increase in attainable output power assumes that the amplifier is not current limited or that the output signal is not clipped. To ensure minimum output sig- nal clipping when choosing an amplifier’s closed-loop gain, refer to the Audio Power Amplifier Design section. Another advantage of the differential bridge output is no net DC voltage across the load. This is accomplished by biasing channel A’s and channel B’s outputs at half-supply. This eliminates the coupling capacitor that single supply, single- ended amplifiers require. Eliminating an output coupling ca- pacitor in a single-ended configuration forces a single-supply amplifier’s half-supply bias voltage across the load. This increases internal IC power dissipation and may perma- nently damage loads such as speakers. POWER DISSIPATION Power dissipation is a major concern when designing a successful single-ended or bridged amplifier. Equation (2) states the maximum power dissipation point for a single- ended amplifier operating at a given supply voltage and driving a specified output load. P DMAX =(VDD) 2/(2 π2R L) Single-Ended (2) However, a direct consequence of the increased power de- livered to the load by a bridge amplifier is higher internal power dissipation for the same conditions. The LM4849 has two operational amplifiers per channel. The maximum internal power dissipation per channel operating in the bridge mode is four times that of a single-ended ampli- fier. From Equation (3), assuming a 5V power supply and a 4 Ω load, the maximum single channel power dissipation is 1.27W or 2.54W for stereo operation. P DMAX =4*(VDD) 2/(2 π2R L) Bridge Mode (3) www.national.com 13 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |