| 数据搜索系统,热门电子元器件搜索 |
|
SP6128A 数据表(PDF) 7 Page - Exar Corporation |
|
|
|||||||||||||||||||||||||||||
SP6128A 数据表(HTML) 7 Page - Exar Corporation |
|
7 / 10 page ![]() 7 Rev. 08/19/05 SP6128A Low Voltage, Synchronous Step Down PWM Controller © Copyright 2005 Sipex Corporation SP6128A OVER CURRENT (HICCUP MODE) Test Conditions V FB = 0.7V V CC = PVCC = 5.0V A more detailed description of the waveform is shown below. Over Current Protection Over current protection on the SP6128A is imple- mented through detection of an excess voltage condition across the high side NMOS switch during conduction. This is typically referred to as high side RDS(ON) detection and eliminates the need of an external sense resistor. The over current comparator charges an internal sam- pling capacitor each time VSWN is lower than (VISET- 140mV) and the GH voltage is high. The discharge/charge current ratio on the sampling capacitor is about 2%. Therefore, provided that the over current condition persists, the capacitor voltage will be pumped up during each time GH switches high. This voltage will trigger an over current condition upon reaching a CMOS in- verter threshold. There are many advantages to this approach. First, the filtering action of the gated scheme protects against false and undesir- able triggering that could occur during a minor transient overload condition or supply line noise. Furthermore, the total amount of time to trigger the fault depends on the on-time of the high side NMOS switch. Fifteen, 1 µs pulses are equiva- lent to thirty, 500ns pulses or one, 15 µs pulse, however, depending on the period, each sce- nario takes a different amount of total time to trigger a fault. Therefore, the fault becomes an indicator of average power in the high side BST = 5.0V SWN - tied to GND through 1k Resistor COMP – released from GND Internal SSTART passes V(VFB), COMP pops to ~ internal SSTART voltage +0.7V Internal SSTART rises until ~ VCC-1V, then gives command to attempt RESTART COMP Clamps ~ 3V After pop, COMP retains internal SSTART slope ENABLE Part Attempt RESTART 5µA PULLUP slope to 0.3V; 35µA PULLUP to 0.7V Overcurrent Detected GH Turns Off Fault Mode Enabled GH COMP OPERATION: continued |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |