| 数据搜索系统,热门电子元器件搜索 |
|
LMP2234AMA/NOPB 数据表(PDF) 20 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LMP2234AMA/NOPB 数据表(HTML) 20 Page - Texas Instruments |
|
20 / 31 page ![]() VO = -K (2a + 1) (V1 - V2) VO = KR2 R2 (VO2 - VO1) = -K (VO1 - VO2) R11 = V1 - V2 V VO1 - VO2 = (2R1 + ) I R11 R 11 = (2a + 1) V R 11 = (2a + 1) R11 x IR 11 GIVEN: I R1 = I R11 LMP2234 SNOSAW4D – SEPTEMBER 2007 – REVISED MARCH 2013 www.ti.com There are two stages in this amplifier. The last stage, the output stage, is a differential amplifier. In an ideal case the two amplifiers of the first stage, the input stage, would be configured as buffers to isolate the inputs. However they cannot be connected as followers because of mismatch in amplifiers. That is why there is a balancing resistor between the two. The product of the two stages of gain will give the gain of the instrumentation amplifier. Ideally, the CMRR should be infinite. However the output stage has a small non-zero common mode gain which results from resistor mismatch. In the input stage of the circuit, current is the same across all resistors. This is due to the high input impedance and low input bias current of the LMP2234. (3) By Ohm’s Law: (4) However: (5) So we have: VO1–VO2 = (2a+1)(V1–V2) (6) Now looking at the output of the instrumentation amplifier: (7) Substituting from Equation 6: (8) This shows the gain of the instrumentation amplifier to be: −K(2a+1) (9) Typical values for this circuit can be obtained by setting: a = 12 and K = 4. This results in an overall gain of −100. SINGLE SUPPLY STRAIN GAUGE BRIDGE AMPLIFIER Strain gauges are popular electrical elements used to measure force or pressure. Strain gauges are subjected to an unknown force which is measured as the deflection on a previously calibrated scale. Pressure is often measured using the same technique; however this pressure needs to be converted into force using an appropriate transducer. Strain gauges are often resistors which are sensitive to pressure or to flexing. Sense resistor values range from tens of ohms to several hundred kilo-ohms. The resistance change which is a result of applied force across the strain gauge might be 1% of its total value. An accurate and reliable system is needed to measure this small resistance change. Bridge configurations offer a reliable method for this measurement. Bridge sensors are formed of four resistors, connected as a quadrilateral. A voltage source or a current source is used across one of the diagonals to excite the bridge while a voltage detector across the other diagonal measures the output voltage. Bridges are mainly used as null circuits or to measure differential voltages. Bridges will have no output voltage if the ratios of two adjacent resistor values are equal. This fact is used in null circuit measurements. These are particularly used in feedback systems which involve electrochemical elements or human interfaces. Null systems force an active resistor, such as a strain gauge, to balance the bridge by influencing the measured parameter. 20 Submit Documentation Feedback Copyright © 2007–2013, Texas Instruments Incorporated Product Folder Links: LMP2234 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |