| 数据搜索系统,热门电子元器件搜索 |
|
CAP1206 数据表(PDF) 39 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
CAP1206 数据表(HTML) 39 Page - Microchip Technology |
|
39 / 63 page ![]() 2013-2015 Microchip Technology Inc. DS00001567B-page 39 CAP1206 5.17 Recalibration Configuration Register The Recalibration Configuration register controls some recalibration routine settings (see Section 4.4, "Sensor Input Calibration") as well as advanced controls to program the Sensor Input Threshold register settings. Bit 7 - BUT_LD_TH - Enables setting all Sensor Input Threshold registers by writing to the Sensor Input 1 Threshold register. • ‘0’ - Each Sensor Input X Threshold register is updated individually. • ‘1’ (default) - Writing the Sensor Input 1 Threshold register will automatically overwrite the Sensor Input Threshold registers for all sensor inputs (Sensor Input Threshold 1 through Sensor Input Threshold 6). The individual Sensor Input X Threshold registers (Sensor Input 2 Threshold through Sensor Input 6 Threshold) can be individually updated at any time. Bit 6 - NO_CLR_INTD - Controls whether the accumulation of intermediate data is cleared if the noise status bit is set. • ‘0’ (default) - The accumulation of intermediate data is cleared if the noise status bit is set. • ‘1’ - The accumulation of intermediate data is not cleared if the noise status bit is set. APPLICATION NOTE: Bits 5 and 6 should both be set to the same value. Either both should be set to ‘0’ or both should be set to ‘1’. Bit 5 - NO_CLR_NEG - Controls whether the consecutive negative delta counts counter is cleared if the noise status bit is set. ‘0’ (default) - The consecutive negative delta counts counter is cleared if the noise status bit is set. ‘1’ - The consecutive negative delta counts counter is not cleared if the noise status bit is set. Bits 4 - 3 - NEG_DELTA_CNT[1:0] - Determines the number of negative delta counts necessary to trigger a digital reca- libration (see Section 4.4.2, "Negative Delta Count Recalibration"), as shown in Table 5-30. Bits 2 - 0 - CAL_CFG[2:0] - Determines the update time and number of samples of the automatic recalibration routine (see Section 4.4.1, "Automatic Recalibration"). The settings apply to all sensor inputs universally (though individual sen- sor inputs can be configured to support recalibration - see Section 5.10.1). TABLE 5-29: RECALIBRATION CONFIGURATION REGISTERS Addr R/W Register B7 B6 B5 B4 B3 B2 B1 B0 Default 2Fh R/W Recalibration Configuration BUT_ LD_TH NO_CLR _INTD NO_CLR _NEG NEG_DELTA_ CNT[1:0] CAL_CFG[2:0] 8Ah TABLE 5-30: NEG_DELTA_CNT BIT DECODE NEG_DELTA_CNT[1:0] Number of Consecutive Negative Delta Count Values 10 00 8 0 1 16 (default) 10 32 1 1 None (disabled) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |