| 数据搜索系统,热门电子元器件搜索 |
|
MCP2003AT-E/P 数据表(PDF) 4 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP2003AT-E/P 数据表(HTML) 4 Page - Microchip Technology |
|
4 / 34 page ![]() MCP2003/4/3A/4A DS20002230F-page 4 2010-2014 Microchip Technology Inc. 1.3 Modes of Operation For an overview of all operational modes, refer to Table 1-1. 1.3.1 POWER-DOWN MODE In Power-Down mode, everything is off except the wake-up section. This is the lowest power mode. The receiver is off, thus its output is open-drain. On CS going to a high level or a falling edge on WAKE (MCP2003/MCP2003A only), the device will enter Ready mode as soon as internal voltage stabilizes. Refer to Section 2.4 “AC Specifications” for further information. In addition, LIN bus activity will change the device from Power-down mode to Ready mode; MCP2003/4 wakes-up on a falling edge on LBUS, followed by a low level lasting at least 20 µs. MCP2003A/4A wakes-up on a rising edge on LBUS, followed by a high level lasting 70 µs typically. See Figures 1-2 to 1-5 about remote wake-up. If CS is held high as the device transitions from Power-Down to Ready mode, the device will transition to either Operation or Transmitter Off mode, depending on TXD input, as soon as internal voltages stabilize. 1.3.2 READY MODE Upon entering the Ready mode, VREN is enabled and the receiver detect circuit is powered up. The transmit- ter remains disabled and the device is ready to receive data but not to transmit. Upon VBB supply pin power-on, the device will remain in Ready mode as long as CS is low. When CS transitions high, the device will either enter Operation mode, if TXD pin is held high, or the device will enter Transmitter Off mode, if TXD pin is held low. 1.3.3 OPERATION MODE In this mode, all internal modules are operational. The device will go into Power-Down mode on the falling edge of CS. For the MCP2003/4 device, a specific process should be followed to put all nodes into Power- Down mode. Refer to Section 1.6 “MCP2003/4 and MCP2003A/4A Difference Details” and Figure 1-6. The device will enter Transmitter Off mode in the event of a Fault condition, such as: thermal overload, bus contention and TXD timer expiration. The MCP2004/2004A device can also enter Transmitter Off mode if the FAULT/TXE pin is pulled low. The VBB to LBUS pull-up resistor is connected only in Operation mode. 1.3.4 TRANSMITTER OFF MODE Transmitter Off mode is reached whenever the transmitter is disabled either due to a Fault condition or pulling the FAULT/TXE pin low on the MCP2004/2004A. The Fault conditions include: thermal overload, bus contention, RXD monitoring or TXD timer expiration. The device will go into Power-Down mode on the falling edge of CS, or return to Operation mode if all faults are resolved and the FAULT/TXE pin on the MCP2004/2004A is high. FIGURE 1-2: OPERATIONAL MODES STATE DIAGRAM – MCP2003 POR VREN OFF RX OFF TX OFF VBAT > 5.5V Ready VREN ON RX ON TX OFF TOFF Mode VREN ON RX ON TX OFF Operation Mode VREN ON RX ON TX ON POWER DOWN VREN OFF RX OFF TX OFF CS = 1& TXD = 0 CS = 1& TXD = 1 CS = 1& TXD = 1& No Fault Fault (thermal or timer) CS = 0 Falling edge on LIN or CS = 1 or falling edge on WAKE pin CS = 0 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |