| 数据搜索系统,热门电子元器件搜索 |
|
GD25Q32C 数据表(PDF) 21 Page - ELM Electronics |
|
|
|||||||||||||||||||||||||||||
GD25Q32C 数据表(HTML) 21 Page - ELM Electronics |
|
21 / 50 page ![]() 21 Rev.1.0 50 - http://www.elm-tech.com GD25Q32CxIGx 3.3V Uniform Sector Dual and Quad Serial Flash Quad I/O Fast Read with “Continuous Read Mode” The Quad I/O Fast Read command can further reduce command overhead through setting the “Continuous Read Mode” bits (M7-0) after the input 3-byte address (A23-A0). If the “Continuous Read Mode” bits (M5-4) =(1, 0), then the next Quad I/O Fast Read command (after CS# is raised and then lowered) does not require the EBH command code. The command sequence is shown in followed Figure14. If the “Continuous Read Mode” bits (M5-4) do not equal to (1, 0), the next command requires the first EBH command code, thus returning to normal operation. A “Continuous Read Mode” Reset command can be used to reset (M5-4) before issuing normal command. Figure 13. Quad I/O Fast Read Sequence Diagram (M5-4 ≠ (1, 0)) Command 0 1 2 3 4 5 6 7 EBH CS# SCLK SI(IO0) SO(IO1) 8 9 10 11 12 13 14 15 4 0 4 0 4 0 4 0 16 17 18 19 20 21 22 23 4 0 4 0 5 1 5 1 5 1 5 1 5 1 5 1 A23-16 A15-8 A7-0 M7-0 6 2 6 2 6 2 6 2 6 2 6 2 7 3 7 3 7 3 7 3 7 3 7 3 WP#(IO2) HOLD#(IO3) 4 5 6 7 Dummy Byte1 Byte2 Figure 14. Quad I/O Fast Read Sequence Diagram (M5-4 = (1, 0)) 0 1 2 3 4 5 6 7 CS# SCLK 8 9 10 11 12 13 14 15 SI(IO0) SO(IO1) WP#(IO2) HOLD#(IO3) 4 0 4 0 5 1 5 1 6 2 6 2 7 3 7 3 4 0 4 0 5 1 5 1 6 2 6 2 7 3 7 3 4 0 4 0 5 1 5 1 6 2 6 2 7 3 7 3 4 5 6 7 A23-16 A15-8 A7-0 M7-0 Dummy Byte1 Byte2 Quad I/O Fast Read with “8/16/32/64-Byte Wrap Around” in Standard SPI mode The Quad I/O Fast Read command can be used to access a specific portion within a page by issuing “Set Burst with Wrap” (77H) commands prior to EBH. The “Set Burst with Wrap” (77H) command can either enable or disable the “Wrap Around” feature for the following EBH commands. When “Wrap Around” is enabled, the data being accessed can be limited to either an 8/16/32/64-byte section of a 256-byte page. The output data starts at the initial address specified in the command, once it reaches the ending boundary of the 8/16/32/64-byte section, the output will wrap around the beginning boundary automatically until CS# is pulled high to terminate the command. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |