6 / 10 page ![]() sames SA2002D 6/10 http://www.sames.co.za Direction input (DIRI) Energy Direction Selection The DIRI input pin allows the representation of the measured energy to be selected. The representation can be of any three types: Pulses are generated on the output if the energy flow is positive. Any negative energy (reverse energy) flow is disregarded. Pulses are generated on the output if the energy flow is negative. Any positive energy flow is disregarded. Negative energy flow is defined as the condition where the voltage sense input and current sense input are out of phase (greater than 90 degrees). Pulses are generated on the output if the energy flow is positive or negative. The energy direction may be ascertained by monitoring the DIRO pin. Positive Energy Negative Energy Bi-direct OUTPUT SIGNALS Motor Pulse Output (MOP, MON) These outputs can be used to drive an electromechanical counter directly at 100 (200) impulses per kWh. See table 1. DIRI Direction 1 0 DIRO Positive Negative Bi-direct Fast Calibration (FAST) The SA2002D may be put in a fast calibration mode by setting FAST to V . In this mode the pulse rate is 1252Hz on the LED output at rated conditions. DD Figure 5: Motor output MON and MOP VDD VDD VSS VSS MON MOP t m t m t m DR-01559 t = 230ms m LED Output (LED) The LED pulse output follows the average power consumption measured and is intended for calibration purposes. The pulse rate is dependant on the settings of pins R0, R1 and R2 (see rated conditions select). The LED output is active low. The LED waveform is shown below: Figure 6: LED pulse output LED t LED DR-01332 VDD VSS An integrated anti-creep function prevents any output pulses if the measured power is less than 0.02% of the meters rated current. The SA2002D provides information about the energy flow direction on pin DIRO. A logic 0 on pin DIRO indicates reverse energy flow. Reverse energy flow is defined as the condition where the voltage sense input and current sense input are out of phase (90..270 degrees). Positive energy flow, when voltage sense and current sense input are in phase, is indicated on pin DIRO as a logic 1. The DIRO pin may be used to drive a LED in order to indicate reverse energy. Direction Indication (DIRO) T = 10ms LED |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |