15 / 22 page ![]() TSC2003 15 SBAS162D www.ti.com Address Byte The address byte, as shown in Figure 10, is the first byte received following the START condition from the master device. The first five bits (MSBs) of the slave address are factory preset to 10010. The next two bits of the address byte are the device select bits: A1 and A0. Input pins (A1-A0) on the TSC2003 determine these two bits of the device address for a particular TSC2003. Therefore, a maximum of four devices with the same preset code can be connected on the same bus at one time. FIGURE 10. Address Byte. 1 0 0 1 0 A1 A0 R/W MSB LSB FIGURE 11. Command Byte. C3 C2 C1 C0 PD1 PD0 M X MSB LSB C3 C2 C1 C0 FUNCTION INPUT to ADC X-DRIVERS Y-DRIVERS REFERENCE MODE 0 0 0 0 Measure TEMP0 TEMP0 OFF OFF Single-Ended 0 0 0 1 Measure VBAT1 VBAT1 OFF OFF Single-Ended 0 0 1 0 Measure IN1 IN1 OFF OFF Single-Ended 0 0 1 1 Reserved –– – Single-Ended 0 1 0 0 Measure TEMP1 TEMP1 OFF OFF Single-Ended 0 1 0 1 Measure VBAT2 VBAT2 OFF OFF Single-Ended 0 1 1 0 Measure IN2 IN2 OFF OFF Single-Ended 0 1 1 1 Reserved –– – Single-Ended 1 0 0 0 Activate X– Drivers – ON OFF Differential 1 0 0 1 Activate Y– Drivers – OFF ON Differential 1 0 1 0 Activate Y+, X– Drivers – X– ON Y+ ON Differential 1 0 1 1 Reserved –– – Differential 1 1 0 0 Measure X Position Y+ ON OFF Differential 1 1 0 1 Measure Y Position X+ OFF ON Differential 1 1 1 0 Measure Z1 Position X+ X– ON Y+ ON Differential 1 1 1 1 Measure Z2 Position Y– X– ON Y+ ON Differential TABLE I. Possible Input Configurations. The internal reference voltage can be turned ON or OFF independently of the A/D converter. This can allow extra time for the internal reference voltage to settle to its final value prior to making a conversion. Make sure to allow this extra wake- up time if the internal reference was powered down. Also note that the status of the internal reference power down is latched into the part (internally) when a STOP or repeated START occurs at the end of a command byte (see Figures 12 and 14). Therefore, in order to turn the internal reference OFF, an additional write to the TSC2003, with PD1 = 0, is required after the channel has been converted. It is recommended to set PD0 = 0 in each command byte to get the lowest power consumption possible. If multiple X-, Y-, and Z-position measurements will be done one right after another, such as when averaging, PD0 =1 will leave the touch screen drivers on at the end of each conversion cycle. • M: Mode bit. If M is 0, the TSC2003 is in 12-bit mode. If M is 1, 8-bit mode is selected. • X: Don’t care. The A1-A0 Address Inputs can be connected to VDD or digital ground. The last bit of the address byte (R/W) defines the operation to be performed. When set to a “1”, a read operation is selected; when set to a “0”, a write operation is selected. Following the START condition, the TSC2003 monitors the SDA bus and checks the device type identifier being transmitted. Upon receiving the 10010 code, the ap- propriate device select bits, and the R/W bit, the slave device outputs an acknowledge signal on the SDA line. Command Byte The TSC2003’s operating mode is determined by a com- mand byte, which is shown in Figure 11. PD1 PD0 PENIRQ DESCRIPTION 0 0 Enabled Power-Down Between Conversions 0 1 Disabled Internal reference OFF, ADC(1) ON 1 0 Enabled Internal reference ON, ADC(1) OFF 1 1 Disabled Internal reference ON, ADC(1) ON NOTE: (1) ADC = Analog-to Digital Converter. TABLE II. Power-Down Bit Functions. The bits in the device command byte are defined as follows: • C3-C0: Configuration bits. These bits set the input multi- plexer address and functions that the TSC2003 will per- form, as shown in Table I. • PD1-PD0: Power-down bits. These two bits select the power-down mode that the TSC2003 will be in after the current command completes, as shown in Table II. When the TSC2003 powers up, the power-down mode bits need to be written to ensure that the part is placed into the desired mode to achieve lowest power. Therefore, immedi- ately after power-up, a command byte should be sent which sets PD1 = PD0 = 0, so that the device will be in the lowest power mode, powering down between conversions. Start A Conversion/Write Cycle A Conversion/Write Cycle begins when the master issues the address byte containing the slave address of the TSC2003, with the eighth bit equal to a 0 (R/W = 0), as shown in Figure 10. Once the eighth bit has been received, and the address matches the A1-A0 address input pin setting, the TSC2003 issues an acknowledge. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |