| 数据搜索系统,热门电子元器件搜索 |
|
TAS5026 数据表(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TAS5026 数据表(HTML) 21 Page - Texas Instruments |
|
21 / 48 page ![]() Architecture Overview 16 SLES041B—November 2002 TAS5026 2.2.2 Power Down—PDN The TAS5026 can be placed into the power-down mode by holding the PDN terminal low. When power-down mode is entered, both the PLL and the oscillator are shut down. Volume is immediately set to full attenuation (there is no ramp down). The valid 1–6 outputs are immediately asserted low and the PWM outputs are placed in the hard mute state. PDN initiates device power down without clock inputs. As long as the PDN terminal is held low—the device is in the power-down (hard mute) state. During power down, all I2C and serial data bus operations are ignored. Table 2–8 shows the device output signals while PDN is active. Table 2–8. Device Outputs During Power Down SIGNAL MODE SIGNAL STATE Valid 1–Valid 6 All Low PWM P-outputs All Low PWM M-outputs All Low MCLKOUT All Low SCLK Master Low SCLK Slave Signal input LRCLK Master Low LRCLK Slave Signal input SDA All Signal input CLIP All High To place the device in total power-down mode, both RESET and power-down modes must be enabled. Prior to bringing PDN high, RESET must be brought low for a minimum of 50 ns. Because PDN is an asynchronous control signal, small clicks and pops can be produced during the application (the leading edge) of this control. However, when PDN is released, the transition from the hard mute state back to normal operation is performed synchronously using a quiet sequence. If a completely quiet reset sequence is desired, MUTE should be applied before applying PDN. 2.2.2.1 Recovery Time Options To support the requirements of various system configurations, the TAS5026 can come up to the normal state after either a long (100 ms) or a short (5 ms) delay. 1. In the first case, a slow system (95 ms to 100 ms) start-up occurs at the end of the power-down sequence when: RESET is high for at least 16 MCLK_IN periods before PDN goes high. 2. Otherwise a fast (4 ms to 5 ms) start up occurs. NOTE: If MCLK_IN is not active when both of these signals are released high, then a a fast (4 ms to 5 ms) start up occurs once MCLK_IN becomes active. 2.2.3 Status Registers The TAS5026 provides device identification and operational status information that is accessible through the serial control interface status registers that provide general device information. Device ID—The TAS5026 provides a device identification code that is accessible through the serial control interface Volume Update is in Progress—Whenever a volume change is in progress, this status bit is high. No Internal Errors (All Valid Signals are High)—When there are no internal errors in the TAS5026 and all outputs are valid, this status bit is high. LRCLK Error—When there are the MCLK_IN rate changes more than ±10 MCLK_IN cycles from the correct number of cycles (128 or 256) per LRCLK cycle MCLK_IN Error—When the MCLK_IN frequency changes such that it is out of synchronization with internal PLL generated clock |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |