| 数据搜索系统,热门电子元器件搜索 |
|
LPQ352-C 数据表(PDF) 2 Page - Artesyn Technologies |
|
|
|||||||||||||||||||||||||||||
LPQ352-C 数据表(HTML) 2 Page - Artesyn Technologies |
|
2 / 4 page ![]() LPQ350 Series Data Sheet Logic Control Power fail TTL logic signal goes high 50 - 150 msec after 5 V output. It goes low at least 4 msec before loss of regulation Remote on/off Requires an external contact (N.O or N.C) to inhibit outputs DC-OK TTL logic goes high 50 - 150 msec after 5 V output. It goes low when there is loss of regulation Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected Environmental Specifications Operating temperature 0° to 50 °C ambient; derate each output at 2.5% per degree from 50° to 70 °C Storage temperature -40 °C to +85 °C Temperature coefficient ± 0.4% per °C Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5Hz to 500Hz, operational MTBF demonstrated > 550,000 hours at full load and 25 °C ambient conditions Ordering Information Model Number Output Voltaqe Minlmun Load Maximum Load Peak Load1 Requlation2 Ripple P/P(PARD)3 LPQ352-C +5 V 5 A 50 A 60 A ±2% 50 mV +12 V 0 A 12 A 14 A ±3% 120 mV -12 V 0 A 6 A 8 A ±3% 120 mV 3.3 - 24 V *1 A 6 A 8 A ±3% 240 mV 1 max. LPQ353-C +5 V 5 A 50 A 60 A ±2% 50 mV +15 V 0 A 12 A 14 A ±3% 150 mV -15 V 0 A 6 A 8 A ±3% 150 mV 3.3 - 24 V *1 A 6 A 8 A ±3% 240 mV 1 max. 1. Peak current lasting < 30 seconds with a maximum 10% duty cycle. 2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 4. 4th output 3.3 - 24 V factory set at 5 V. 5. * Minimum load required when the output is set below 5 volts. 6. If optional CF or CEF fans are not used, 30CFM forced air cooling needs to be provided and is required through the length of the power supply. Not convection rated. 7. Remote inhibit resets OVP latch Note: -CF suffix added to the model number indicates cover with fan, -CEF suffix added to model number indicates end-mounted fan chassis. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |