18 / 37 page ![]() MCS3142 DS40001747A-page 18 2014 Microchip Technology Inc. 5.0 ULTIMATE KEELOQ TECHNOLOGY OPERATION 5.1 Synchronization Counter The synchronization counter is an always-incrementing, event-based counter. The counter is incremented whenever a new button combination is registered and a new code word is prepared. For increased security, the synchronization counter will not overflow. The device will cease operating when the counter reaches its maximum value. The initial value of the synchronization counter may be set via the Synchronization Counter Initial Value registers (see Table 3-21). 5.2 Encoder Time-Stamp MCS3142 requires an external 31.768 kHz oscillator connected to the secondary oscillator drive pins of the internal timer. This timer is used to track the passage of time over the lifetime of the encoder. Each Ultimate KEELOQ transmission includes this time with quarter-second resolution (i.e., each count represents one quarter of a second). The initial value of the timer may be set at programming time via the Timer Initial Value registers, described in Table 3-24. 5.3 Function Code The function code is a bitmapped representation of the state of each button on the transmitter. States are active-high. 5.4 Battery Level and Low Battery Flag Each Ultimate KEELOQ transmission contains a battery level indicator byte. It includes a 7-bit digital representation of the battery level and a 1-bit low battery flag. The battery level is captured by measuring an on-board 1.024V source using the battery as reference. The low battery flag is high whenever the measured battery voltage is estimated to be below 2.5V. Equation 5-1 converts the reference value into a voltage. EQUATION 5-1: 5.5 Button Press Timer The button press timer is a high-resolution timer representing the duration of the current button press at the time the code word was prepared. Each count represents 50 ms of time. It resets whenever a new button combination is registered. 5.6 Delta Time The delta time represents the elapsed time since the previous code word was sent. The timer increments every second. 5.7 Reset Counter The Reset counter is an always-incrementing counter representing the number of Power-on Reset events experienced by the device. It is intended to be used by the receiver as an indication that the transmitter has been without power and that there will be a discrepancy in the time-stamp. For increased security, the Reset counter will not overflow. The device will cease operating when the counter reaches its maximum value. The initial value of the Reset counter may be set using the Reset Counter Configuration registers, described in Table 3-23. TABLE 5-1: ULTIMATE KEELOQ® FUNCTION CODE TRANSLATION Button Function Code S0 xxx1 S1 xx1x S2 x1xx S3 1xxx VBAT 1.024 2 7 BATT ------------------------- = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |