3 / 8 page ![]() K Hours --- --- 1000 MIL-HDBK-217F @ 25], Ground Benign MTBF ] 117 112 107 Case Temperature, automatic recovery Over Temperature Protection KHz 360 330 290 Switching Frequency pF 1500 1200 --- 100KHz,1V Isolation Capacitance M[ --- --- 1000 500VDC Isolation Resistance VDC --- --- 1650 Flash Tested for 1 Second Isolation Voltage Test VDC --- --- 1500 60 Seconds Isolation Voltage Rated Unit Max. Typ. Min. Conditions Parameter General Specifications Continuous Output Short Circuit %/] {0.02 {0.01 --- Temperature Coefficient % {4 {2 --- Transient Response Deviation uS 300 150 --- 25% Load Step Change Transient Recovery Time % 180 --- 120 Over Power Protection mV rms 10 --- --- Ripple & Noise (20MHz) mV P-P 100 --- --- Over Line, Load & Temp. Ripple & Noise (20MHz) mV P-P 80 55 --- Ripple & Noise (20MHz) % {1.0 {0.3 --- Io=50% to 100% Load Regulation % {0.5 {0.2 --- Vin=Min. to Max. Line Regulation % {2.0 {0.5 --- Dual Output, Balanced Loads Output Voltage Balance % {1.0 {0.5 --- Output Voltage Accuracy Unit Max. Typ. Min. Conditions Parameter Output Specifications Referenced to Negative Input Control Common uA -100 --- --- Vin -RC = 0V Control Input Current ( off ) uA 5 --- --- Vin -RC = 5.0V Control Input Current ( on ) mA 5 2 --- Device Standby Input Current VDC 1 --- -1 Supply Off VDC 2.5 to 100VDC or Open Circuit Supply On Unit Max. Typ. Min. Conditions Parameter Remote On/Off Control % {11.0 {10.0 {9.0 % of nominal output voltage Trim Up / Down Range Unit Max. Typ. Min. Conditions Parameter Output Voltage Trim Notes1: 1. Specifications typical at Ta=+25], resistive load, nominal input voltage, rated output current unless otherwise noted. 2. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%. 3. Ripple & Noise measurement bandwidth is 0-20 MHz. 4. These power converters require a minimum output loading to maintain specified regulation. 5. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 6. All DC/DC converters should be externally fused at the front end for protection. 7. Other input and output voltage may be available, please contact factory. 8. Specifications subject to change without notice. MPW2000 Series Total Power International, Inc. Toll Free: 877-646-0900(US) www.total-power.com |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |