2 / 9 page ![]() Input Fuse CPCI AC Rev. 00 Page 2 of 9 www.powersystemtechnology.com A fuse mounted inside the converter protects against damages in case of a failure. The fuse is not user-accessible. In DC mode, reverse polarity at the input is protected and will not cause the fuse to blow . Model Fuse type Ra�ng Reference CPCI AC Schurter 5A 340300173 Input Transient Protec�on A VDR (Voltage Dependent Resistor) and a common mode input filter form an effec�ve protec�on against input transients in severe environments. Electrical Input Data MIL-STD ruggedized (M) Meet MIL-STD 461E CE102, MIL-STD 1399-300A, MIL-STD810E shock & vibra�ons. Laboratory cer�fica�on. -40°C opera�on (T) The thermal grade of the Vicor the DC/DC converters used and other components are changed to comply with low ambiant temperature. Op�ons Descrip�on Unit Characteristics Conditions min typ max Operating input voltage 85 265 Vac Operating input voltage 100 350 Vdc Frequency 44 50 440 Hz Power Factor 230Vac, 50Hz, Pnom. 0,96 0,98 Input current At Vin min 4,1 A No-load input power At Vin typ 15 W Peak inrush current Vin max 4 A Start-up time 1 s Input Electrical Output Data General condi�ons : 25°C ambiant. Output Output Efficiency curve Power factor curve Establisment �me curve Unit Characteristics Conditions min typ max min typ max min typ max min typ max Output voltage 5 3V3 12 -12 V Set point accuracy 4,95 5,05 3,26 3,33 11,5 12,5 -11,5 -12,5 V Trim range 4,5 5,5 3 3,6 V Overvoltage protection 5,66 3,8 13,6 -13,6 V Output current 0 40 0 50 0 1 0 1 A Output current limit 48 59 1,5 1,5 A Output noise 20MHz 75 50 90 90 mVpp Line Regulation Vout nom. 0,05 0,05 0,05 0,05 % Load Regulation Vin nom. 0,1 0,1 1 3 % Output V1 V2 V3 V4 Max output power 325W overall Conformal coa�ng (V) During manufacturing process , when V op�on is specified, components and pcb are covered with an acrylic coa�ng to address high level of ambiant humidity applica�on. 61000-4-5 (Y) Include a common mode surge protec�on 61000-4-5 Level 3 2KV based on gas discharger and VDR to meet criteria A. BE CAREFUL not to apply dielectric test if this op�on is choosen. If no Y op�on, criteria B is met. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |