| 数据搜索系统,热门电子元器件搜索 |
|
IXDP630PI 数据表(PDF) 3 Page - IXYS Corporation |
|
|
|||||||||||||||||||||||||||||
IXDP630PI 数据表(HTML) 3 Page - IXYS Corporation |
|
3 / 7 page ![]() I - 16 © 1998 IXYS All rights reserved IXDP630 IXDP631 Sym. Pin Description GND 9 CIRCUIT GROUND - 0 Volts RCIN 10 The first node of the clock or network. For the IXDP630, the XTLIN RC input is applied to RCIN. For the IXDP 631, the crystal oscil- lator is applied to XTLIN. If an external clock is to be supplied to the chip it should be connec- ted to this pin. OSC 11 This is the output node of the OUT oscillator. It is connected indi- rectly to the RCIN or XTLIN pins when using the internal oscillator as described in the applications information. It is not recommen- ded for external use. TL 12 After the appropriate delay, the TU 13 external drive outputs (R,S, T) U SL 14 are in phase with their corres- SU 15 ponding inputs; (R,S, T) L are RL 16 the complementary outputs. RU 17 V CC 18 Voltage Supply +5 V ± 10 % Sym. Pin Description R 1 R, S and T are the three single- S 3 phase inputs. Each input is T 5 expanded into two outputs to generate non-overlapping drive signals, RU/RL, SU/SL, and TU/ TL. The delay from the falling edge of one line to the rising edge of the other is a function of the clock. ENAR 2 High logic input will enable the ENAS 4 outputs, as set by the proper ENAT 6 input phase. The ENA (R,S,T) signals control the drive output lines. A low logic input will force both controlled outputs to a low logic level OUT 7 High logic level will enable all ENA outputs to their related phase. The OUTENA simultaneously controls all outputs. Low input logic level will inhibit all outputs (low). RESET 8 The RESET signal is active low. When a logic low RESET is applied, all outputs will go low. After releasing the RESET command within the generated delay, the outputs will align with the phase input level after the programmed delay internal. Pin Description IXDP630 Pin Description IXDP631 Waveforms deadtime deadtime deadtime deadtime This diagram shows the normal operation of the IXDP630/631 after the RESET input is released. The DEADTIME is the 8 Clock periods between XU and XL when both XU and XL are a "0". The length of the DEADTIME is fixed at 8 times the period of CLK. Thediagram shows OUTENA and ENAX asynchronously forcing the XU Output and the XL Output to the off state. OUTENA will force all three channels to the off state. ENAX (where X is one of the three channels) will only force the XU and XL Outputs of that channel to the off state. Note that because ENAX is asynchronous with respect to the internal clock and deadtime counters, when ENAX goes HI whatever state the deadtime counter was in immediately propagates to the output. This figure also shows that noise at the XIN input will be filtered before the XU Output or XL Output will become active, which may extend the deadtime. Note: X = Any input, R, S or T. noise deadtime deadtime |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |