Back Button DPS310 Datasheet HTML 10Page - Infineon Technologies AG DPS310 Datasheet HTML 11Page - Infineon Technologies AG DPS310 Datasheet HTML 12Page - Infineon Technologies AG DPS310 Datasheet HTML 13Page - Infineon Technologies AG DPS310 Datasheet HTML 14Page - Infineon Technologies AG DPS310 Datasheet HTML 15Page - Infineon Technologies AG DPS310 Datasheet HTML 16Page - Infineon Technologies AG DPS310 Datasheet HTML 17Page - Infineon Technologies AG DPS310 Datasheet HTML 18Page - Infineon Technologies AG Next Button
Zoom Inzoom in Zoom Outzoom out
 14 / 41 page
background image
4.9.1
How to Calculate Compensated Pressure Values
Steps
1. Read the pressure calibration coefficients (c00, c10, c20, c30, c01, c11, and c21) from the Calibration
Coefficient register.
Note:
The coefficients read from the coefficient register are 2's complement numbers.
2. Choose scaling factors kT (for temperature) and kP (for pressure) based on the chosen precision rate. The
scaling factors are listed in Table 9 .
3. Read the pressure and temperature result from the registers or FIFO.
Note:
The measurements read from the result registers (or FIFO) are 24 bit 2´s complement numbers.
Depending on the chosen measurement rates, the temperature may not have been measured
since the last pressure measurement.
4. Calculate scaled measurement results.
Traw_sc = Traw/kT
Praw_sc = Praw/kP
5. Calculate compensated measurement results.
Pcomp(Pa) = c00 + Praw_sc*(c10 + Praw_sc *(c20+ Praw_sc *c30)) + Traw_sc *c01 +
Traw_sc *Praw_sc *(c11+Praw_sc*c21)
4.9.2
How to Calculate Compensated Temperature Values
Steps
1. Read the temperature calibration coefficients ( c0 and c1 ) from the Calibration Coefficients (COEF) register.
Note:
The coefficients read from the coefficient register are 12 bit 2´s complement numbers.
2. Choose scaling factor kT (for temperature) based on the chosen precision rate. The scaling factors are listed
in Table 9 .
3. Read the temperature result from the temperature register or FIFO.
Note:
The temperature measurements read from the temperature result register (or FIFO) are 24 bit 2´s
complement numbers.
4. Calculate scaled measurement results.
Traw_sc = Traw/kT
5. Calculate compensated measurement results.
DPS310 - Digital Pressure Sensor
Digital Barometric Pressure Sensor for Portable Devices
Functional Description
14
V1.0
2016-09-05



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com