| 数据搜索系统,热门电子元器件搜索 |
|
EC2 数据表(PDF) 3 Page - NEC |
|
|
|||||||||||||||||||||||||||||
EC2 数据表(HTML) 3 Page - NEC |
|
3 / 8 page ![]() 3 DATA SHEET ER0002EJ4V0DS00 EC2 SERIES PART NUMBER SYSTEM EC2 – 9 S NU Nil : Standard type NU : UL recognized, CSA certified type NJ : Trimed leads type ∗ NP : Silver-palladium alloy contact (with gold alloy overlay) ∗ Latch type Nil : Non-latch type S : Single coil latch type T : Double coil latch type Nominal coil voltage 3, 4.5, 5, 6, 9, 12, 24 V EC2 series ∗ UL recognized, CSA certified type 2 Form c Silver alloy with gold alloy overlay 60 W, 125 VA 220 Vdc, 250 Vac 2 A 2 A 10 mVdc, 10 µA ∗1 50 m Ω typ. (Initial) 140 mW (3 to 12 V), 200 mW (24 V) 100 mW 140 mW Approx. 2 ms Approx. 1 ms without diode 1000 M Ω at 500 Vdc 1000 Vac (for one minute) 1500 V surge (10 × 160 µs ∗2) 1500 Vac (for one minute) Double Coil 1000 Vac (for one minute) 2500 V surge, (2 × 10 µs ∗3) Latch type 1500 V surge (10 × 160 µs ∗2) 735 m / s2 (75 G) (misoperating) 980 m / s2 (100 G) (destructive failure) 10 to 55 Hz double amplitude of 3 mm (20 G) (misoperating) 10 to 55 Hz, double amplitude of 5 mm (30 G) (Destructive failure) –40 to 85˚C 18 degrees at nominal coil voltage (140 mW) 1 × 108 ∗4 operations (Non-latch type) 1 × 107 operations (latch type) 50 Vdc, 0.1 A (resistive) 1 × 106 operations at 85˚C, 2 Hz 10 Vdc, 10 mA (resistive) 1 × 106 operations at 85˚C, 2 Hz Approx. 1.9 g Contact Form Contact Material Maximum Switching Power Maximum Switching Voltage Maximum Switching Current Maximum Carrying Current Minimum Contact Ratings Initial Contact Resistance Non-Latch Type Nominal Operating Power Single Coil Latch Type Single Coil Latch Type Operate Time (Excluding Bounce) Release Time (Excluding Bounce) Insulation Resistance Between Open Contacts Breakdown Voltage Between Adjacent Contacts Between Coil and Contact Shock Resistance Vibration Resistance Ambient Temperature Coil Temperature Rise No-load Load Weight PERFORMANCE CHARACTERISTICS Running specifications Contact Ratings (UL / CSA Rating) ∗1 This value is reference value in the resistance load. Minimum capacity changes depending on switching frequency and environment temperatur and the load. ∗2 rise time : 10 µs, fall time : 160 µs ∗3 rise time : 2 µs, fall time : 10 µs ∗4 This shows a number of operation where it can be running by which a fatal defect is not caused, and a number of operation by whicha steady characteristic is maintained is 1 × 107 times. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |