39 / 59 page ![]() USB Port Power Controller with Charger Emulation Datasheet SMSC UCS1001 39 Revision 1.2 (05-21-12) DATASHEET 6.3.1.1 Dynamic Thermal Management For the first stage (active in both current limiting modes), referred to as dynamic thermal management, the UCS1001 automatically adjusts port power switch limits and modes to lower power dissipation when the thermal regulation temperature value is approached, as described below. If the internal temperature exceeds the TREG value, the port power switch is opened, the current limit (ILIM) will be lowered by one step and a timer is started (tDC_TEMP). When this timer expires, the port power switch is closed and the internal temperature will be checked again. If it remains above the TREG threshold, the UCS1001 will repeat this cycle (open port power switch and reduce the ILIM setting by one step) until ILIM reaches its minimum value. APPLICATION NOTE: If the temperature exceeds the TREG threshold while operating in the DCE Cycle mode after a charger emulation profile has been accepted, the profile will be removed. The UCS1001 will not restart the DCE Cycle until one of the control inputs changes states to restart emulation. APPLICATION NOTE: The UCS1001 will not actively discharge VBUS as a result of the temperature exceeding TREG; however, any load current provided by a portable device or other load will cause VBUS to be discharged when the port power switch is opened, possibly resulting in an attached portable device resetting. If the UCS1001 is operating using constant current limiting (variable slope) and the ILIM setting has been reduced to its minimum set point and the temperature is still above TREG, the UCS1001 will switch to operating using trip current limiting. This will be done by reducing the IBUS_R2MIN setting to 100 mA and restoring the ILIM setting to the value immediately below the programmed setting (e.g., if the programmed ILIM is 1.8 A, the value will be set to 1.5 A). If the temperature continues to remain above TREG, the UCS1001 will continue this cycle (open the port power switch and reduce the ILIM setting by one step). If the UCS1001 internal temperature drops below TREG - TREG_HYST, the UCS1001 will take action based on the following: 1. If the current limit mode changed from CC mode to trip mode, then a timer is started. When this timer expires, the UCS1001 will reset the port power switch operation to its original configuration allowing it to operate using constant current limiting (variable slope). 2. If the current limit mode did not change from CC mode to trip mode, or was already operating in trip mode, the UCS1001 will reset the port power switch operation to its original configuration. If the UCS1001 is operating using trip current limiting and the ILIM setting has been reduced to its minimum set point and the temperature is above TREG, the port power switch will be closed and the current limit will be held at its minimum setting until the temperature drops below TREG - TREG_HYST. 6.3.1.2 Thermal Shutdown The second stage thermal management consists of a hardware implemented thermal shutdown corresponding to the maximum allowable internal die temperature (TTSD). If the internal temperature exceeds this value, the port power switch will immediately be turned off until the temperature is below TTSD - TTSD_HYST. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |