数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

LELBMA-CQ 数据表(PDF) 23 Page - OSRAM GmbH

部件名 LELBMA-CQ
功能描述  Compact lightsource in SMT technology
PDF  23 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  OSRAM [OSRAM GmbH]
网页  http://www.osram.com
标志 OSRAM - OSRAM GmbH

LELBMA-CQ 数据表(HTML) 23 Page - OSRAM GmbH

Back Button LELBMA-CQ Datasheet HTML 15Page - OSRAM GmbH LELBMA-CQ Datasheet HTML 16Page - OSRAM GmbH LELBMA-CQ Datasheet HTML 17Page - OSRAM GmbH LELBMA-CQ Datasheet HTML 18Page - OSRAM GmbH LELBMA-CQ Datasheet HTML 19Page - OSRAM GmbH LELBMA-CQ Datasheet HTML 20Page - OSRAM GmbH LELBMA-CQ Datasheet HTML 21Page - OSRAM GmbH LELBMA-CQ Datasheet HTML 22Page - OSRAM GmbH LELBMA-CQ Datasheet HTML 23Page - OSRAM GmbH  
Zoom Inzoom in Zoom Outzoom out
 23 / 23 page
background image
Version 2.0
LE RTDUW S2W
2014-09-10
23
Fußnoten:
1)
Helligkeitswerte werden während eines Strompulses
einer typischen Dauer von 25 ms, mit einer internen
Reproduzierbarkeit von +/- 8 % und einer erweiterten
Messunsicherheit von +/- 11 % gemessen (gemäß
GUM mit Erweiterungsfaktor k = 3).
2)
Wegen der besonderen Prozessbedingungen bei der
Herstellung von LED können typische oder abgeleitete
technische Parameter nur aufgrund statistischer Werte
wiedergegeben
werden.
Diese
stimmen
nicht
notwendigerweise mit den Werten jedes einzelnen
Produktes überein, dessen Werte sich von typischen
und abgeleiteten Werten oder typischen Kennlinien
unterscheiden können. Falls erforderlich, z.B. aufgrund
technischer Verbesserungen, werden diese typischen
Werte ohne weitere Ankündigung geändert.
3)
Die dominante Wellenlänge wird während eines
Strompulses einer typischen Dauer von 25 ms, mit
einer internen Reproduzierbarkeit von +/- 0,5 nm und
einer erweiterten Messunsicherheit von +/- 1 nm
gemessen
(gemäß GUM mit Erweiterungsfaktor
k = 3).
4)
Vorwärtsspannungen
werden
während
eines
Strompulses einer typischen Dauer von 8 ms, mit
einer internen Reproduzierbarkeit von +/- 0,05 V und
einer erweiterten Messunsicherheit von +/- 0,1 V
gemessen (gemäß GUM mit Erweiterungsfaktor k=3).
5)
Im gestrichelten Bereich der Kennlinien muss mit
erhöhten
Helligkeitsunterschieden
zwischen
Leuchtdioden
innerhalb
einer
Verpackungseinheit
gerechnet werden.
6)
Maße werden wie folgt angegeben: mm (inch).
7)
Ein
kritisches
Bauteil
ist
ein
Bauteil,
das
in
lebenserhaltenden
Apparaten
oder
Systemen
eingesetzt wird und dessen Defekt voraussichtlich zu
einer Fehlfunktion dieses lebenserhaltenden Apparates
oder Systems führen wird oder die Sicherheit oder
Effektivität
dieses
Apparates
oder
Systems
beeinträchtigt.
8)
Lebenserhaltende Apparate oder Systeme sind für (a)
die Implantierung in den menschlichen Körper
oder
(b) für die Lebenserhaltung bestimmt.
Falls sie versagen, kann davon ausgegangen werden,
dass die Gesundheit und das Leben des Patienten in
Gefahr ist.
Published by
OSRAM Opto Semiconductors GmbH
Leibnizstraße 4, D-93055 Regensburg
www.osram-os.com
© All Rights Reserved.
Remarks:
1)
Brightness values are measured during a current
pulse of typical 25 ms, with an internal reproducibility
of +/- 8 % and an expanded uncertainty of +/- 11 %
(acc. to GUM with a coverage factor of k = 3).
2)
Due to the special conditions of the manufacturing
processes of LED, the typical data or calculated
correlations of technical parameters can only reflect
statistical figures. These do not necessarily correspond
to the actual parameters of each single product, which
could differ from the typical data and calculated
correlations or the typical characeristic line.
If requested, e.g. because of technical improvements,
these typ. data will be changed without any further
notice.
3)
The dominant wavelength is measured at a current
pulse of typical 25 ms, with an internal reproducibility
of +/- 0,5 nm and an expanded uncertainty of +/- 1 nm
(acc. to GUM with a coverage factor of k=3)
4)
The forward voltage is measured during a current
pulse of typical 8 ms, with an internal reproducibility of
+/- 0,05 V and an expanded uncertainty of +/- 0,1 V
(acc. to GUM with a coverage factor of k=3).
5)
In the range where the line of the graph is broken, you
must expect higher brightness differences between
single LEDs within one packing unit.
6)
Dimensions are specified as follows: mm (inch).
7)
A critical component is a component used in a
life-support device or system whose failure can
reasonably be expected to cause the failure of that
life-support device or system, or to affect its safety or the
effectiveness of that device or system.
8)
Life support devices or systems are intended
(a) to be implanted in the human body,
or
(b) to support and/or maintain and sustain human life. If
they fail, it is reasonable to assume that the health and
the life of the user may be endangered.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com