2 / 4 page ![]() 408-10129 SDE Die Sets 1804039-1 and 1976357-1 Rev D 2 of 4 Tyco Electronics Corporation Figure 2 Wire Stop Metal Wire Crimp Sleeve Translucent Plastic Outer Sleeve Upper Crimp Die Wire Lower Crimp Die Wire Terminal Upper Crimp Die Lower Crimp Die Terminal Splice 5. If a splice is being crimped, repeat Steps 2 to 4 for the other crimp side of the splice. If splice cannot be turned for crimping other half, turn the tool around. Damaged splices should not be used. If a damaged splice is evident, it should be removed and replaced with a new one. Splices should not be reterminated. 5. CRIMP INSPECTION Inspect crimped terminals and splices by checking to make sure the splice has been crimped in the center of the wire barrel. Poor crimps can be avoided by carefully following the procedures provided in Section 4, and by following the tool maintenance procedures provided in your hand tool instruction sheet. 6. DIE INSPECTION 6.1. Visual Inspection Inspection of the crimping dies should be made on a regular basis to ensure that they have not become worn or damaged. Inspect the crimp sections for flattened, chipped, worn, or broken areas. If damage or abnormal wear is evident, the dies must be replaced. 6.2. Measured Die Opening The dies will perform properly as long as: (1) the product specified is correct for the application, (2) the specified die set is used, (3) the die set has been measured to ensure that the openings are correct, and (4) the dies bottoms. 7. CRIMP HEIGHT INSPECTION This inspection requires the use of plug gages conforming to the dimensions provided in Figure 3. Tyco Electronics does not manufacture or market these gages. To gage the crimping chamber, proceed as follows: 1. Remove traces of oil or dirt from the crimping chamber and plug gage. 2. Close the tool handles, or cycle the crimp tooling until the dies have bottomed. Do NOT force dies beyond initial contact. 3. Align the GO element with the crimping chamber. Push element straight into the crimping chamber without using force. The GO element must pass completely through the crimping chamber. See Figure 3. 4. Align the NO–GO element and try to insert it straight into the same crimping chamber. The NO–GO element may start entry, but must not pass completely through the crimping chamber. See Figure 3. If the crimping chamber conforms to the gage inspection, the dies are considered dimensionally correct, and should be lubricated with a THIN coat of any good SAE 20 motor oil. If not, the dies must be returned to Tyco Electronics for further evaluation. Refer to Section 7, REPAIR/REPLACEMENT. For additional information regarding the use of a plug gage, refer to Tyco Electronics Instruction Sheet 408–7424. 8. REPAIR/REPLACEMENT If the dies do not meet the GO, NO–GO gage dimensions provided in Figure 3, the tool and/or dies are defective and must be replaced. Order replacements through your Tyco Electronics Representative, or call 1–800–526–5142, or send a facsimile of your purchase order to 717–986–7605, or write to: CUSTOMER SERVICE (038–035) TYCO ELECTRONICS CORPORATION PO BOX 3608 HARRISBURG PA 17105–3608 NOTE i CAUTION ! |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |