2 / 5 page ![]() 408- 9085 Terminating Head 58062- 1 Rev B 2 of 5 Tyco Electronics Corporation Figure 2 Clip Ramp Adapter Slide Adapter Into Slot Installing Adapter (Used for Single-Row Connectors Only) 4. TERMINATION PROCEDURE Make sure that the connector matches the wire size to be terminated, then refer to Figure 3, and proceed as follows: 1. Align the side of the connector with the side of the head (so that it will move in the direction of the arrow), and slowly slide the connector into the feed channel. Stop when the desired contact position aligns with the wire slot. If the connector cannot be inserted into the head or if the connector is too loose in the head, refer to Paragraph 5.2 for wire guide adjustment. 2. Insert the wire into the wire slot until the wire bottoms on the head. Figure 3 Wire Wire Slot Slide Connector Into Feed Channel Power Unit (Ref) Connector (Double Row Shown) Terminating Connector 3. Center the wire in the wire slot, then actuate the power unit until the wire inserter bottoms (the wire inserter will retract and the connector will advance to the next contact position). 4. Center the wire in the wire slot, then actuate the power unit until the wire inserter bottoms (the wire inserter will retract and the connector will advance to the next contact position). 5. Repeat Steps 1 through 3 until all applicable contacts are terminated. 6. Slide the connector out of the head in the direction of the arrow. 7. Inspect each terminated contact according to Figure 4. If any contact does not meet the requirements, DO NOT use the connector. Refer to Section 5 for adjustments. For application requirements for the connectors, refer to the appropriate application specification: 114--25019 for single--row connectors and 114--25032 for double--row connectors. 5. ADJUSTMENTS For pneumatic power units, to avoid personal injury, ALWAYS disconnect the air supply before making adjustments to the head. For electric power units, to prevent personal injury, ALWAYS disconnect the electrical power supply before making adjustments to the head. 5.1. Wire Insertion Depth If the wire is inserted too deep or not deep enough in the contact after termination, adjust the wire insertion depth as follows: A. Pneumatic Power Units Increase the air pressure by 10 psi [69 kPa]. Repeat the termination and inspection procedure. Continue in this manner until the proper wire insertion depth is obtained or the air pressure is set to 70 psi [483 kPa]. If proper wire insertion depth is not obtained at 70 psi [483 kPa], return the air pressure to 40 psi [276 kPa] and follow Paragraph B. For pneumatic power units, it might be necessary to adjust either the wire insertion depth or the air pressure. NOTE i NOTE i DANGER DANGER NOTE i |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |