| 数据搜索系统,热门电子元器件搜索 |
|
SHT10 数据表(PDF) 3 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
SHT10 数据表(HTML) 3 Page - List of Unclassifed Manufacturers |
|
3 / 12 page ![]() www.sensirion.com Version 5 – December 2011 3/12 Users Guide SHT1x 1 Application Information 1.1 Operating Conditions Sensor works stable within recommended normal range – see Figure 4. Long term exposures to conditions outside normal range, especially at humidity >80%RH, may temporarily offset the RH signal (+3 %RH after 60h). After return to normal range it will slowly return towards calibration state by itself. See Section 1.4 “Reconditioning Procedure” to accelerate eliminating the offset. Prolonged exposure to extreme conditions may accelerate ageing. Normal Range 0 20 40 60 80 100 -40 -20 0 20 40 60 80 100 120 Temperature (°C) Figure 4: Operating Conditions 1.2 Soldering instructions For soldering SHT1x standard reflow soldering ovens may be used. The sensor is qualified to withstand soldering profile according to IPC/JEDEC J-STD-020D with peak temperatures at 260°C during up to 40sec including Pb- free assembly in IR/Convection reflow ovens. Figure 5: Soldering profile according to JEDEC standard. TP <= 260°C and tP < 40sec for Pb-free assembly. TL < 220°C and tL < 150sec. Ramp-up/down speeds shall be < 5°C/sec. For soldering in Vapor Phase Reflow (VPR) ovens the peak conditions are limited to TP < 233°C during tP < 60sec and ramp-up/down speeds shall be limited to 10°C/sec. For manual soldering contact time must be limited to 5 seconds at up to 350°C7. 7 233°C = 451°F, 260°C = 500°F, 350°C = 662°F IMPORTANT: After soldering the devices should be stored at >75%RH for at least 12h to allow the polymer to re- hydrate. Otherwise the sensor may read an offset that slowly disappears if exposed to ambient conditions. Alternatively the re-hydration process may be performed at ambient conditions (>40%RH) during more than 5 days. In no case, neither after manual nor reflow soldering, a board wash shall be applied. Therefore it is strongly recommended to use “no-clean” solder paste. In case of application with exposure of the sensor to corrosive gases or condensed water (i.e. environments with high relative humidity) the soldering pads shall be sealed (e.g. conformal coating) to prevent loose contacts or short cuts. For the design of the SHT1x footprint it is recommended to use dimensions according to Figure 7. Sensor pads are coated with 35µm Cu, 5µm Ni and 0.1µm Au. Figure 6: Rear side electrodes of sensor, view from top side. Figure 7: Recommended footprint for SHT1x. Values in mm. 1.3 Storage Conditions and Handling Instructions It is of great importance to understand that a humidity sensor is not a normal electronic component and needs to be handled with care. Chemical vapors at high concentration in combination with long exposure times may offset the sensor reading. For these reasons it is recommended to store the sensors in original packaging including the sealed ESD bag at 1.97 2.47 1.07 Ø0.60 3.48 1.8 1.8 7.08 Time tP TP TL TS (max) tL preheating critical zone |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |