20 / 21 page ![]() AD8236 Rev. 0 | Page 19 of 20 LOW POWER HEART RATE MONITOR The low power and small size of the AD8236 make it an excellent choice for heart rate monitors. As shown in Figure 42, the AD8236 measures the biopotential signals from the body. It rejects common-mode signals and serves as the primary gain stage set at G = 5. The 4.7 μF capacitor and the 100 kΩ resistor set the −3 dB cutoff of the high-pass filter that follows the instrumentation amplifier. It rejects any differential dc offsets that may develop from the half-cell overpotential of the electrode. A secondary gain stage, set at G = 403, amplifies the ECG signal, which is then sent into a second-order, low-pass, Bessel filter with −3 dB cutoff at 48 Hz. The 324 Ω resistor and 1 μF capacitor serve as an antialiasing filter. The 1 μF capacitor also serves as a charge reservoir for the ADC’s switched capacitor input stage. This circuit was designed and tested using the AD8609, low power, quad op amp. The fourth op amp is configured as a Schmitt trigger to indicate if the right arm or left arm electrodes fall off the body. Used in conjunction with the 953 kΩ resistors at the inputs of the AD8236, the resistors pull the inputs apart when the electrodes fall off the body. The Schmitt trigger sends an active low signal to indicate a leads off condition. The reference electrode (right leg) is set tied to ground. Likewise, the shield of the electrode cable is also tied to ground. Some portable heart rate monitors do not have a third electrode. In such cases, the negative input of the AD8236 can be tied to GND. Note that this circuit is shown, solely, to demonstrate the capability of the AD8236. Additional effort must be made to ensure compliance with medical safety guidelines. +2.5V +2.5V –2.5V +2.5V –2.5V –2.5V –2.5V 0.1µF 0.1µF 0.1µF +2.5V AD8609 AD8236 IN-AMP AD8609 AD8609 AD8609 +2.5V –2.5V LEADS OFF DETECTION INTERRUPT LEADS OFF 402kΩ 1kΩ 1kΩ 24.9kΩ 324Ω 1µF 220nF 4.7µF 100kΩ 953kΩ RA LA RL 953kΩ 1kΩ 20kΩ 5kΩ 680nF 4.02kΩ MCU + ADC 10-BIT ADC 0.1µF Figure 42. Example Low Power Heart Rate Monitor Schematic |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |