| 数据搜索系统,热门电子元器件搜索 |
|
ADM7171ACPZ-1.3-R7 数据表(PDF) 21 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM7171ACPZ-1.3-R7 数据表(HTML) 21 Page - Analog Devices |
|
21 / 24 page ![]() ADM7171 Data Sheet Rev. C | Page 20 of 23 Thermal overload protection is included, which limits the junction temperature to a maximum of 150°C (typical). Under extreme conditions (that is, high ambient temperature and/or high power dissipation) when the junction temperature starts to rise above 150°C, the output is turned off, reducing the output current to zero. When the junction temperature drops below 135°C, the output is turned on again, and the output current is restored to its operating value. Consider the case where a hard short from VOUT to ground occurs. At first, the ADM7171 current limits, so that only 3 A is conducted into the short. If self heating of the junction is great enough to cause its temperature to rise above 150°C, thermal shutdown activates, turning off the output and reducing the output current to zero. As the junction temperature cools and drops below 135°C, the output turns on and conducts 3 A into the short, again causing the junction temperature to rise above 150°C. This thermal oscillation between 135°C and 150°C causes a current oscillation between 3 A and 0 mA that continues for as long as the short remains at the output. Current-limit and thermal limit protections are intended to protect the device against accidental overload conditions. For reliable operation, device power dissipation must be externally limited so that the junction temperature does not exceed 125°C. THERMAL CONSIDERATIONS In applications with low input-to-output voltage differential, the ADM7171 does not dissipate much heat. However, in applications with high ambient temperature and/or high input voltage, the heat dissipated in the package may become large enough that it causes the junction temperature of the die to exceed the maximum junction temperature of 125°C. When the junction temperature exceeds 150°C, the converter enters thermal shutdown. It recovers only after the junction temperature has decreased below 135°C to prevent any permanent damage. Therefore, thermal analysis for the chosen application is very important to guarantee reliable performance over all conditions. The junction temperature of the die is the sum of the ambient temperature of the environment and the tempera- ture rise of the package due to the power dissipation, as shown in Equation 2. To guarantee reliable operation, the junction temperature of the ADM7171 must not exceed 125°C. To ensure that the junction temperature stays below this maximum value, the user must be aware of the parameters that contribute to junction temperature changes. These parameters include ambient temperature, power dissipation in the power device, and thermal resistances between the junction and ambient air (θJA). The θJA number is dependent on the package assembly compounds that are used and the amount of copper used to solder the package GND pin to the PCB. Table 7 shows typical θJA values of the 8-lead LFCSP package for various PCB copper sizes. The typical value of ΨJB is 15.1°C/W for the 8-lead LFCSP package. Table 7. Typical θJA Values Copper Size (mm2) θJA (°C/W) of LFCSP 251 165.1 100 125.8 500 68.1 1000 56.4 6400 42.1 1 Device soldered to minimum size pin traces. The junction temperature of the ADM7171 is calculated from the following equation: TJ = TA + (PD × θJA) (2) where: TA is the ambient temperature. PD is the power dissipation in the die, given by PD = [(VIN − VOUT) × ILOAD] + (VIN × IGND) (3) where: ILOAD is the load current. IGND is the ground current. VIN and VOUT are the input and output voltages, respectively. Power dissipation due to ground current is quite small and can be ignored. Therefore, the junction temperature equation simplifies to the following: TJ = TA + (((VIN − VOUT) × ILOAD) × θJA) (4) As shown in Equation 4, for a given ambient temperature, input- to-output voltage differential, and continuous load current, a minimum copper size requirement exists for the PCB to ensure that the junction temperature does not rise above 125°C. Figure 63 to Figure 65 show junction temperature calculations for differ- ent ambient temperatures, power dissipation, and areas of PCB copper. Figure 63. LFCSP, TA = 25°C TOTAL POWER DISSIPATION (W) 6400mm2 500mm2 25mm2 TJ MAX 25 35 45 55 65 75 85 95 105 115 125 135 145 155 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |