9 / 15 page ![]() 1.0 Functional Description (Continued) and T_CRIT_A outputs. The fault queue is enabled by set- ting bit 4 of the Configuration Register high (see Section 1.11). 1.8 INTERNAL REGISTER STRUCTURE There are four data registers in the LM76, selected by the Pointer register. At power-up the Pointer is set to “00”; the lo- cation for the Temperature Register. The Pointer register latches the last location it was set to. In Interrupt Mode, a read from the LM76 resets the INT output. Placing the device in Shutdown mode resets the INT and T_CRIT_A outputs. All registers are read and write, except the Temperature register which is read only. A write to the LM76 will always include the address byte and the Pointer byte. A write to the Configuration register re- quires one data byte, while the T LOW,THIGH, and T_CRIT registers require two data bytes. Reading the LM76 can take place either of two ways: If the location latched in the Pointer is correct (most of the time it is expected that the Pointer will point to the Temperature regis- ter because it will be the data most frequently read from the LM76), then the read can simply consist of an address byte, followed by retrieving the corresponding number of data bytes. If the Pointer needs to be set, then an address byte, pointer byte, repeat start, and another address byte plus re- quired number of data bytes will accomplish a read. The first data byte is the most significant byte with most sig- nificant bit first, permitting only as much data as necessary to be read to determine the temperature condition. For in- stance, if the first four bits of the temperature data indicates a critical condition, the host processor could immediately take action to remedy the excessive temperature. At the end of a read, the LM76 can accept either Acknowledge or No Acknowledge from the Master (No Acknowledge is typically used as a signal for the slave that the Master has read its last byte). An inadvertent 8-bit read from a 16-bit register, with the D7 bit low, can cause the LM76 to stop in a state where the SDA line is held low as shown in Figure 4. This can prevent any further bus communication until at least 9 additional clock cycles have occurred. Alternatively, the master can issue clock cycles until SDA goes high, at which time issuing a “Stop” condition will reset the LM76. DS101015-7 DS101015-8 FIGURE 4. Inadvertent 8-Bit Read from 16-Bit Register where D7 is Zero (“0”) www.national.com 9 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |