| 数据搜索系统,热门电子元器件搜索 |
|
CS10.243 数据表(PDF) 6 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CS10.243 数据表(HTML) 6 Page - PULS GmbH |
|
6 / 25 page ![]() CS10.243 C-Line 24V, 10A, SINGLE PHASE INPUT 4. DC-INPUT Do not operate this power supply with DC-input voltage. Use the CP10.241 or CP10.242 units instead. 5. INPUT INRUSH CURRENT A NTC inrush limitation circuit limits the input inrush current after turn-on of the input voltage. The charging current into the EMI suppression capacitors is disregarded in the first microseconds after switch-on. AC 100V AC 120V Inrush current max. 90Apeak 108Apeak at +40°C ambient, cold start typ. 71Apeak 85Apeak at +40°C ambient, cold start Inrush energy max. 6A2s 8.5A2s at +40°C ambient, cold start Fig. 5-1 Typical input inrush current behavior 1 > 2 > 3 3 > Input: 120Vac Output: 24V, 10A Ambient: +40°C Upper curve: Input current (50A / DIV) Medium curve: Input voltage (100V / DIV) Lower curve: Output voltage (10V / DIV) Time scale: 20ms / DIV Jul. 2015 / Rev. 2.0 DS-CS10.243-EN All parameters are specified at 24V, 10A, 120Vac, 60Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 6/25 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|