21 / 23 page ![]() QT20.361 Q-Series 36V, 13.3A, THREE PHASE INPUT Oct. 2006 / Rev. 1.0 DS-QT20.361-EN All parameters are specified at 36V, 13.3A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 27.8. PARALLEL USE TO INCREASE OUTPUT POWER Power supplies can be paralleled to increase the output power. Fig. 27-10 Schematic for parallel operation Instructions for parallel use: Unit B - + Load + - Fuse *) Fuse *) AC DC AC DC - + Unit A a) Use only power supplies from the same series (Q-Series). b) Adjust the output voltages of all power supplies to approximately the same value (±500mV). Otherwise, the DC-ok signal might not work properly. c) A fuse (or diode) on the output is only required if more than three units are connected in parallel. d) Keep an installation clearance of 15mm (left / right) between two power supplies and avoid installing the power supplies on top of each other. 27.9. PARALLEL USE FOR REDUNDANCY Power supplies can be paralleled for redundancy to gain a higher system availability. Redundant systems require a certain amount of extra power to support the load in case one power supply unit fails. The simplest way is to put two Q-Series power supplies in parallel. This is called a 1+1 redundancy. In case one power supply unit fails, the other one is automatically able to support the load current without any interruption. Redundant systems for a higher power demand are usually built in a N+1 method. E.g. Five power supplies, each rated for 10A are paralleled to build a 40A redundant system. Please note: This simple way to build a redundant system does not cover failures such as an internal short circuit in the secondary side of the power supply. In such a - virtually nearly impossible - case, the defect unit becomes a load for the other power supplies and the output voltage can not be maintained any more. This can only be avoided by utilizing decoupling diodes which are included in the decoupling module YR2.DIODE. (One module per power supply) Recommendations for building redundant power systems: a) Use separate input fuses for each power supply. b) Monitor the individual power supply units. A DC-ok lamp and a DC-ok contact is already included in the units This feature reports a faulty unit. c) When possible, connect each power supply to different phases or circuits. d) It is desirable to set the output voltages of all power supplies to the same value to avoid a false DC-ok signal. 27.10.DAISY CHAINING OF OUTPUTS Daisy chaining (jumping from one power supply output to the next) is allowed as long as the maximum current through one terminal pin does not exceed 25A. If the current is higher, use a separate distribution terminal block. Fig. 27-11 Daisy chaining of outputs Fig. 27-12 Using distribution terminals Power Supply + + - - Input Power Supply + + - - Input Load + - max 25A! Power Supply + + - - Input Power Supply + + - - Input Load + - Distribution Terminals 21/23 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |