| 数据搜索系统,热门电子元器件搜索 |
|
STK17TA8-R 数据表(PDF) 16 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
STK17TA8-R 数据表(HTML) 16 Page - List of Unclassifed Manufacturers |
|
16 / 22 page ![]() STK17TA8 February 2004 16 Document Control # ML0023 rev 0.3 output. Only one source is necessary to drive the pin. The user can identify the source by reading the Flags/Control register, which contains the flags associated with each source. All flags are cleared to 0 when the register is read. The cycle must be a complete read cycle (WE high); otherwise the flags will not be cleared. The power monitor has two pro- grammable settings that are explained in the power monitor section. Once an interrupt source is active, the pin driver determines the behavior of the output. It has two programmable settings as shown below. Pin driver control bits are located in the Interrupts register. According to the programming selections, the pin can be driven in the backup mode for an alarm inter- rupt. In addition, the pin can be an active low (open- drain) or an active high (push-pull) driver. If pro- grammed for operation during backup mode, it can only be active low. Lastly, the pin can provide a one- shot function so that the active condition is a pulse or a level condition. In one-shot mode, the pulse width is internally fixed at approximately 200 ms. This mode is intended to reset a host microcontrol- ler. In level mode, the pin goes to its active polarity until the Flags/Control register is read by the user. This mode is intended to be used as an interrupt to a host microcontroller. The control bits are summa- rized as follows: Watchdog Interrupt Enable - WIE. When set to 1, the watchdog timer drives the INT pin as well as an internal flag when a watchdog timeout occurs. WhenWIE is set to 0, the watchdog timer affects only the internal flag. Alarm Interrupt Enable - AIE. When set to 1, the alarm match drives the INT pin as well as an internal fla. When set to 0, the alarm match only affects to internal flag. Power Fail Interrupt Enable - PFE. When set to 1, the power fail monitor drives the pin as well as an internal flag. When set to 0, the power fail monitor affects only the internal flag. Alarm Battery-backup Enable - ABE. When set to 1, the clock alarm interrupt (as controlled by AIE) will function even in battery backup mode. When set to 0, the alarm will occur only when Vcc>Vswitch. AIE should only be set when the INT pin is programmed for active low operation. In addition, it only functions with the clock alarm, not the watchdog. If enabled, the power monitor will drive the interrupt during all normal Vcc conditions regardless of the ABE bit. The application for ABE is intended for power con- trol, where the system powers up at a predeter- mined time. Depending on the application, it may require dedicating the INT pin to this function. High/Low - H/L. When set to a 1, the INT pin is active high and the driver mode is push-pull. The INT pin can drive high only when Vcc>Vswitch. When set to a 0, the INT pin is active low and the drive mode is open-drain. Active low (open drain) is operational even in battery backup mode. Pulse/Level - P/L. When set to a 1 and an interrupt occurs, the INT pin is driven for approximately 200 ms. When P/L is set to a 0, the INT pin is driven high or low (determined by H/L) until the Flags/Control register is read. When an enabled interrupt source activates the INT pin, as external host can read the Flags/Control reg- ister to determine the cause. Remember that all flags will be cleared when the register is read. If the INT pin is programmed for Level mode, then the condition will clear and the INT pin will return to its inactive state. If the pin is programmed for Pulse mode, then reading the flag also will clear the flag and the pin. The pulse will not complete its specified duration if the Flags/Control register is read. If the INT pin is used as a host reset, then the Flags/Con- trol register cannot be read during a reset. During a power-on reset with no battery, the inter- rupt register is automatically loaded with the value 24h. This causes power-fail interrupt to be enabled with an active-low pulse. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |