| 数据搜索系统,热门电子元器件搜索 |
|
WFDEXP 数据表(PDF) 2 Page - Systemsensor advanced ideas. |
|
|
|||||||||||||||||||||||||||||
WFDEXP 数据表(HTML) 2 Page - Systemsensor advanced ideas. |
|
2 / 2 page ![]() 3825OhioAvenue•St.Charles,IL60174 Phone:800-SENSOR2•Fax:630-377-6495 ©2009 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-1030-006•2/09•#1925 Ordering Information Model Number Pipe Size Hole Size Weight WFD20EXP 2˝ 1¼˝ 10.6 lbs. WFD25EXP 2½˝ 1¼˝ 10.7 lbs. WFD30-2EXP 3˝ 2˝ 10.9 lbs. WFD35EXP 3½˝ 1¼˝ 11.2 lbs. WFD40EXP 4˝ 2˝ 11.5 lbs. WFD50EXP 5˝ 2˝ 12.1 lbs. WFD60EXP 6˝ 2˝ 12.5 lbs. WFD80EXP 8˝ 2˝ 13.5 lbs. Accessories A3008-0 Replacement retard mechanism for all sizes 2˝–8˝ A77-01-02 Replacement terminal block WFDRK Replacement hardware kit (contains tamper screws, wrench and conduit plug) WFDEXP Series Specifications Architectural/Engineering Specifications Vane-type,explosion-proofwaterflowdetectorsshallbeinstalledonsystempipingonthedrawingand/orasspecifiedherein.Detectorsshallbemounted in hazardous locations classified as: Class I, Div. 1 and 2, Groups B, C, D; or Class II, Div. 1 and 2, Groups E, F, G; or Class III, Div. 1 and 2. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6˝ from any fittings which may change water direction, flow rate, or pipe diameter or no closer than 24˝ from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi for 2˝–8˝ pipes. The detector shall respond to waterflow in the specified direction after a preset time delay that is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances (one of which is a knockout type) for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or outdoor use. Physical/Operating Specifications Hazardous Locations Classifications Class I, Div 1 and 2, Groups B, C, D Class II, Div 1 and 2, Groups E, F, G Class III, Div 1 and 2 Static Pressure Rating 450 psi (max.) Triggered Threshold Bandwidth (Flow Rate) 4 to 10 GPM Maximum Surge 18 Feet Per Second (FPS) Contact Ratings Two sets of SPDT (Form C) 10.0A@125/250VAC 2.5 A @ 24 VDC Compatible Pipe Steel water pipe, schedule 10 through 40 Conduit Entrances Two openings for ½˝ conduit Operating Temperature Range 32°F to 120°F (0°C to 49°C) Enclosure Rating NEMA4–suitableforindoor/outdooruse Service Use Automatic Sprinkler: NFPA-13 National Fire Alarm Code: NFPA-72 Overall Dimensions 6˝H × 9˝L × 6.5˝W Weight (see Ordering Information) Warranty 3 years U.S. Patent Numbers 5,213,205 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |