| 数据搜索系统,热门电子元器件搜索 |
|
WFDNFS 数据表(PDF) 2 Page - Systemsensor advanced ideas. |
|
|
|||||||||||||||||||||||||||||
WFDNFS 数据表(HTML) 2 Page - Systemsensor advanced ideas. |
|
2 / 2 page ![]() 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2016 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. WFDS85300 • 11/16 Ordering Information UL Model Description WFDNFS Waterflow Detector with Glue In CPVC adapter , Fits 1in., 1¼in., 1½in., 2in. CPVC tees WFDNFT Waterflow Detector with Threaded CPVC adapter , Fits 1in., 1¼in., 1½in., 2in. brass threaded and copper sweat tees; 1in., 1½in. CPVC tees Accessories FS-RT Delay mechanism and switch assembly CTS Tamper-proof switch kit WFDW Tamper-proof wrench for cover Engineering Specifications Model shall be WFDNFS or WFDNFT as manufactured by System Sensor. Waterflow detectors shall be installed on a 1”, 1¼”., 1½”. or 2”. CPVC tee manufactured by Tyco, Spears, NIBBCO, or IPEX as designated on the drawing and /or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run at least 6˝ from any fittings or valves that may change water direction, flow rate, or pipe diameter or no closer than 24in. from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 175 psi. The WFDNFS or WFDNFT detector with incorporated time delay mechanism shall respond to waterflow in the specified direction after a preset time delay that is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual and audible indication of actuation. The actuation mechanism shall include a ethylene vinyl acetate vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or outdoor use. Waterflow Detector Specifications Standard Specifications Static Pressure Rating 175 PSI Operating Temperature Range 32°F to 150°F (0°C to 60°C) Maximum Surge 18 Feet Per Second (FPS) Enclosure Rating* NEMA 4 – suitable for indoor/outdoor use Triggering Threshold Bandwidth (Flow Rate) 4 – 10 GPM Cover Tamper Switch Optional, part no. CTS Conduit Entrances Two openings for ½in. conduit. NEMA 4 rated plugs Service Use Automatic Sprinkler: NFPA-13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4 Stories: NFPA 13R National Fire Alarm Code: NFPA-72 Contact Ratings Two sets of SPDT (Form C) 10.0 A, ½ HP @ 125/250 VAC 2.5 A @ 6/12/24 VDC Compatible Tee Fittings 1” Warranty 3 Years WFDNFS / WFDNFT Field Wiring Diagram Overall Dimensions, Installed WFDNFS, WFDNFT W0400-00 W0401-00 3-1/2" 2-5/8" 4-1/2" TEE DEPTH PLASTIC VANE LOCKING COLLAR TEE ADAPTER TEE FITTING 3-1/2" 2-5/8" TEE DEPTH 4-3/32 PLASTIC VANE LOCKING COLLAR TEE ADAPTER TEE FITTING |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |