| 数据搜索系统,热门电子元器件搜索 |
|
HAL855 数据表(PDF) 21 Page - Micronas |
|
|
|||||||||||||||||||||||||||||
HAL855 数据表(HTML) 21 Page - Micronas |
|
21 / 102 page ![]() APPLICATION NOTE HAL8xy, HAL100x Programmer Board Micronas Sept. 19, 2013; APN000046_03EN 21 4.3. Programming of the Sensor 4.3.1. Definition of Programming Pulses The sensor is addressed by modulating a serial telegram on the supply voltage. The sensor answers with a serial telegram on the output pin. The bits in the serial telegram have a different bit time for the VDD-line and the output. The bit time for the VDD-line is defined through the length of the Sync bit at the begin- ning of each telegram. The bit time for the output is defined through the Acknowledge bit. A logical “0” is coded as no voltage change within the bit time. A logical “1” is coded as a voltage change between 50% and 80% of the bit time. After each bit, a voltage change occurs. 4.3.2. Definition of the Telegram Each telegram starts with the Sync bit (logical 0), 3 bits for the Command (COM), the Command Parity bit (CP), 4 bits for the Address (ADR), and the Address Parity bit (AP). There are 4 kinds of telegrams: Write a register After the AP bit, follow 14 Data bits (DAT) and the Data Parity bit (DP). If the telegram is valid and the command has been processed, the sensor answers with an Acknowledge bit (logical 0) on the output (see Fig. 4–2). Read a register After evaluating this command, the sensor answers with the Acknowledge bit, 14 Data bits, and the Data Parity bit on the output (see Fig. 4–3). Programming the EEPROM cells After evaluating this command, the sensor answers with the Acknowledge bit. After the delay time tw, the supply voltage rises up to the programming voltage (see Fig. 4–4). Activate a sensor If more than one sensor is connected to the supply line, selection can be done by first deactivating all sensors. The output of all sensors will be pulled to ground by the inter- nal 10 k resistors. With an activate pulse on the appropriate output pin, an individual sensor can be selected. All following commands will only be accepted from the acti- vated sensor (see Fig. 4–5). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |