Back Button L99MD01 Datasheet HTML 5Page - STMicroelectronics L99MD01 Datasheet HTML 6Page - STMicroelectronics L99MD01 Datasheet HTML 7Page - STMicroelectronics L99MD01 Datasheet HTML 8Page - STMicroelectronics L99MD01 Datasheet HTML 9Page - STMicroelectronics L99MD01 Datasheet HTML 10Page - STMicroelectronics L99MD01 Datasheet HTML 11Page - STMicroelectronics L99MD01 Datasheet HTML 12Page - STMicroelectronics L99MD01 Datasheet HTML 13Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 54 page
background image
L99MD01
Detailed description
Doc ID 17242 Rev 6
9/54
2.9
Temperature warning and thermal shutdown
If the junction temperature rises above TjTW ON a temperature warning flag is set and is
detectable via the SPI. If the junction temperature increases above the second threshold
TjSD ON, the thermal shutdown bit is set and power DMOS transistors of all output stages
are switched off to protect the device. Temperature warning flag and thermal shutdown bits
are latched. In order to reactivate the output stages, the junction temperature must
decrease below TjSD ON and the thermal shutdown bit has to be cleared by the
microcontroller.
2.10
VS, VS2, VSA, VSB monitoring
VS undervoltage:
Status bit is set. All outputs and SMPS are switched off.
The microcontroller needs to clear the status bits to reactivate the
drivers and SMPS.
VS overvoltage:
Status bit is set. All outputs are switched off (default).
The microcontroller needs to clear the status bits to reactivate the
drivers Can be deactivated via SPI.
VSA undervoltage:
Status bit is set. Out 1 to Out 8 are switched off.
The microcontroller needs to clear the status bits to reactivate the
drivers.
VSB undervoltage:
Status bit is set. Out 1 to Out 8 are switched off.
The microcontroller needs to clear the status bits to reactivate the
drivers.
VS2 undervoltage:
Status bit is set. Only if SPMS is active.
The microcontroller needs to clear the status bits to reactivate SMPS
VS2 overvoltage:
Status bit is set. SMPS is switched off (default).
The microcontroller needs to clear the status bits to reactivate
SMPS. If the VS2 recovery bit is set, and the VS2 voltage falls below
the threshold, the SMPS goes in active mode and the status bit is
cleared.
Table 2.
VS, VS2, VSA, VSB monitoring
‘typ
SMPS
Out x
VS undervoltage
5.7 V
Status + off
Status + off
VS overvoltage
22.0 V
X
Status + (off or mask)
VSA undervoltage
5.7 V
X
Status + off
VSB undervoltage
5.7 V
X
Status + off
VS2 undervoltage
VS + 1.5V
Status
X
VS2 overvoltage
35.0 V
Status + (off or (off+ recovery))



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com