| 数据搜索系统,热门电子元器件搜索 |
|
Z8FS021 数据表(PDF) 39 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
Z8FS021 数据表(HTML) 39 Page - Zilog, Inc. |
|
39 / 68 page ![]() PS028806-0315 Standard API Register Set ZMOTION® Intrusion Detection Product Specification 31 Dual Pyro Mode (Bit 0) Dual Pyroelectric Sensor Signaling Mode; controlled by the application. • This bit determines if the PIR Engine should accept signals from one or two pyroelectric sensors. • When configured for single pyro operation, only one sensor is used (connected to ANA2). When configured for dual pyrooperation, the Engine willscan two sensors simultaneously. Dual pyro mode is typically used to provide a larger area of coverage. The second pyroelectric sensor is connected to input ANA3. In Dual Pyro Mode, motion on either sensor will generate a motion detected event. 0 = Single pyroelectric sensor mode. 1 = Dual pyroelectric sensor mode. Table 10. PIR Status/Control Register 2 (ePIR_SC2) Bit 76543210 Field White Light Threshold Range Control Control Read/Write Read/Write Address 104H Bits 7–3 reserved White Light Detection Threshold* Controlled by application • These bits determine how sensitive the White light detector is to changes in detected white light. Larger values cause the white light detector to be less sensitive. A value of 00000 disables White Light Detection. The light is sensed via the LED connected to the ANA1 pin. Light shining on the LED creates a small current that can generate enough voltage on the pin to measure changes accurately. The PIR Engine automatically configures the ADC to single-ended buffered mode and performs the necessary conversions and processing. See theWhite Light Detection section on page 19 for adescription of White Light operation. Note: *This register is ignored in Low Power Mode; White Light Detection is disabled by Lower Power Mode. Range Control (Bits 2–0) Motion Detection Range Control; controlled by the application. • These bits determine the relative range of motion detection; larger values decrease the range of detection. This parameter acts as a motion signal amplitude check. A smaller range value means that a valid motion signal’s amplitude can be lower. A larger range value means that a valid motion signal’s amplitude must be higher. • Typical values used for range control are dependent on the lens and pyroelectric sensor being used. Range is also dependent on target size, speed and relative temperature. For example, a range control setting that rejects one target of a particular size at a given distance does not guarantee that a larger target will be rejected at the same distance. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |