| 数据搜索系统,热门电子元器件搜索 |
|
Z86L02 数据表(PDF) 19 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
Z86L02 数据表(HTML) 19 Page - Zilog, Inc. |
|
19 / 37 page ![]() Z86C02/E02/L02 Zilog Cost Effective, 512-Byte ROM CMOS Z8® Microcontrollers DS96DZ80301 P R E L I M I N A R Y 19 1 FUNCTIONAL DESCRIPTION The following special functions have been incorporated into the Z86C02/E02/L02 devices to enhance the standard Z8 core architecture to provide the user with increased de- sign flexibility. RESET. This function is accomplished by means of a Pow- er-On Reset or a Watch-Dog Timer Reset. Upon power- up, the Power-On Reset circuit waits for TPOR ms, plus 18 clock cycles, then starts program execution at address 000C (Hex) (Figure 11). The control registers' reset value is shown in Table 4. Power-On Reset (POR). A timer circuit clocked by a ded- icated on-board RC oscillator is used for a POR timer func- tion. The POR time allows VCC and the oscillator circuit to stabilize before instruction execution begins. The POR timer circuit is a one-shot timer triggered by one of the four following conditions: s Power bad to power good status s Stop-Mode Recovery s WDT time-out s WDH time-out (in Halt Mode) s WDT time-out (in Stop Mode) Watch-Dog Timer Reset. The WDT is a retriggerable one-shot timer that resets the Z8 if it reaches its terminal count. The WDT is initially enabled by executing the WDT instruction and is retriggered on subsequent execution of the WDT instruction. The timer circuit is driven by an on- board RC oscillator. If the permanent WDT option is select- ed then the WDT is enabled after reset and operates in RUN Mode, HALT mode, STOP mode and cannot be dis- abled. If the permanent WDT option is not selected then the WDT, when enabled by the user's software, does not operate in STOP Mode, but it can operate in HALT Mode by using a WDH instruction. Figure 11. Internal Reset Configuration POR (Cold Start) P27 (Stop Mode) Delay Line T POR ms 18 CLK Reset Filter Chip Reset XTAL OSC INT OSC Table 4. Control Register Reset Condition Addr Reg. D7 D6 D5 D4 D3 D2 D1 D0 Comments FF SPL 00000000 FE GPR 00000000 FD RP 00000000 FC FLAGS UUUUUUUU FB IMR 0 UUUUUUU FA IRQ U U 000000 IRQ3 is used for positive edge detection F9 IPR UUUUUUUU F8 P01M U U U 0 U U 0 1 F7* P3M UUUUUU 0 0 P2 open-drain F6* P2M 11111111 Inputs after reset F3 PRE1 UUUUUU 0 0 F2 T1 UUUUUUUU F1 TMR 00000000 Note: *Registers are not reset after a STOP-Mode Recovery using P27 pin. A subsequent reset will cause these control registers to be reconfigured as shown in Table 4 and the user must avoid bus contention on the port pins or it may affect device reliability. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |