| 数据搜索系统,热门电子元器件搜索 |
|
GL650USB 数据表(PDF) 9 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
GL650USB 数据表(HTML) 9 Page - List of Unclassifed Manufacturers |
|
9 / 16 page ![]() 9 08/18/00 GL650USB 4 PORT USB HUB CONTROLLER Revision 1.2 HUB_STAT_CHG ( offset 08, default = 00h ) R/O R/O R/O R/O LCPWR OVCUR -- -- -- -- C_LCPWR C_OVCUR HUB status and status change LCPWR : HUB local power status 1’b0 – local power good 1’b1 – local power lost OVRCUR : HUB over current indicator 1’b0 – No over-current condition currently exists 1’b1 – A hub over-current condition exists C_LCPWR : Local power status change 1’b0 – No change has occurred to local power status 1’b1 – local power status has changed C_OVRCUR : HUB over current indicator change 1’b0 – No change has occurred to the over-current indicator 1’b1 – Hub over-current indicator has changed PORT_STATUS ( offset 09, default = 00h ) R/O R/O R/O R/O R/O R/O R/O PT_LOW_ SPD PT_PWR -- PT_RST PT_OVCU R PT_SUS PT_EN PT_CON Port status in dicator: PT_LOW_SPD : 1’b0 – full speed device connected, 1’b1 – low speed device connected PT_PWR : 1’b0 – port is in power off state, 1’b1 – port is not in power off state PT_RST : 1’b0 – Reset signaling not asserted, 1b’1 – Reset signaling assert ed PT_OVCUR : 1’b0 – No over-current condition occurred on this port 1’b1 – An over-current condition exists on this port PT_SUS : 1’b0 – port not suspended, 1’b1 – port suspended or resuming PT_EN : 1’b0 – port is disabled, 1’b1 – port is enabled PT_CON : 1’b0 – No device is present, 1’b1 – A device is present on this port BUS_PORT_DATA ( offset 0A, default = 00h ) R/O R/O R/O R/O R/O R/O R/O VP VM -- C_PT_RST C_PT_ OVCUR C_PT_ SUS C_PT_EN C_PT_ CON Bus state and Port status change in dicator: VP : VP state on the downstream port VM : VM state on the downstream port C_PT_RST : 1’b0 – No change, 1’b1 – Reset complete C_PT_OVCUR : 1’b0 – No change has occurred to over-current indicator 1’b1 – over-current indicator has changed C_PT_SUS : 1’b0 – No change, 1’b1: – Resume complete C_PT_EN : Set to one when a port is disabled because of a Port_error condition C_PT_CON : 1’b0 – No change has occurred to current connect status 1’b1 – Current connect status has changed |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |