| 数据搜索系统,热门电子元器件搜索 |
|
ATS693LSG 数据表(PDF) 4 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
ATS693LSG 数据表(HTML) 4 Page - Allegro MicroSystems |
|
4 / 15 page ![]() Three-Wire, Differential, Vibration Resistant Sensor IC with Speed and Direction Output ATS693LSG 4 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com Characteristic Symbol Test Conditions Min. Typ.1 Max. Unit Performance Characteristics Air Gap Range AG Using Allegro Reference Target 60-0 0.5 – 2.75 mm Vibration Immunity (Startup) errVIB(SU) TTARGET – – deg. Vibration Immunity (Running Mode) errVIB TTARGET – – deg. Input Magnetic Characteristics Allowable Differential Sequential Signal Variation7 BSEQ(n+1) / BSEQ(n) Signal cycle-to-cycle variation (see figure 2) 0.6 – – – Calibration First Direction Output Pulse8 Amount of target rotation (constant direction) following power-on until first electrical output pulse of either tw(FWD) or tw(REV), see figure 1 AG ≥ 0.5 mm AG < 2.25 mm – 2 × TTARGET <3 × TTARGET deg. AG ≥ 2.25 mm AG ≤ 2.75 mm – 2.5 × TTARGET <4 × TTARGET deg. First Direction Pulse Output Following Direction Change NCD 1 × TTARGET 2 × TTARGET <3 × TTARGET deg. First Direction Pulse Output Following Running Mode Vibration 1 × TTARGET 2 × TTARGET <3 × TTARGET deg. 1 Typical values are at TA = 25°C and VCC = 12 V. Performance may vary for individual units, within the specified maximum and minimum limits. 2 Maximum voltage must be adjusted for power dissipation and junction temperature; see Power Derating section. 3 Negative current is defined as conventional current coming out of (sourced from) the specified device terminal. 4 Sustained voltages beyond the clamp voltage may cause permanent damage to the IC. 5 Pulse duration measured at a threshold of VPULLUP/ 2. 6 Maximums of both Operating Frequency (Reverse Rotation) and Operating Frequency (Non-Direction Pulses) are determined by satisfactory separation of output pulses: VOUT(HIGH) of tw(FWD)(min). If the customer can resolve shorter high-state durations, maximum fFWD, fREV, and fND may be increased. 7 If the minimum signal phase separation is not maintained during or after a signal variation event, output may be blanked or non-direction pulses may occur. A signal varia- tion event during power-on may increase the quantity of edges required to get correct direction pulses. 8 Power-on frequency ≤ 200 Hz. Higher power-on frequencies may require more input magnetic cycles until directional output pulses are achieved. OPERATING CHARACTERISTICS (continued): valid throughout full operating and temperature ranges; using Reference Target 60-0; unless otherwise specified |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |