| 数据搜索系统,热门电子元器件搜索 |
|
ICS511 数据表(PDF) 3 Page - Integrated Circuit Systems |
|
|
|||||||||||||||||||||||||||||
ICS511 数据表(HTML) 3 Page - Integrated Circuit Systems |
|
3 / 8 page ![]() LOCOTM PLL Clock Multiplier MDS 511 G 3 Revision 102504 In te gr at ed Circuit Syst ems ● 525 Ra ce St reet , San Jose, CA 9512 6 ● t e l (4 08) 297 -1 201 ● www.icst.com ICS511 External Components Decoupling Capacitor As with any high-performance mixed-signal IC, the ICS511 must be isolated from system power supply noise to perform optimally. A decoupling capacitor of 0.01µF must be connected between VDD and the GND. It must be connected close to the ICS511 to minimize lead inductance. No external power supply filtering is required for the ICS511. Series Termination Resistor A 33 Ω terminating resistor can be used next to the CLK pin for trace lengths over one inch. Crystal Load Capacitors The total on-chip capacitance is approximately 12 pF. A parallel resonant, fundamental mode crystal should be used. The device crystal connections should include pads for small capacitors from X1 to ground and from X2 to ground. These capacitors are used to adjust the stray capacitance of the board to match the nominally required crystal load capacitance. Because load capacitance can only be increased in this trimming process, it is important to keep stray capacitance to a minimum by using very short PCB traces (and no vias) between the crystal and device. Crystal capacitors, if needed, must be connected from each of the pins X1 and X2 to ground. The value (in pF) of these crystal caps should equal (CL -12 pF)*2. In this equation, CL= crystal load capacitance in pF. Example: For a crystal with a 16 pF load capacitance, each crystal capacitor would be 8 pF [(16-12) x 2] = 8. Absolute Maximum Ratings Stresses above the ratings listed below can cause permanent damage to the ICS511. These ratings, which are standard values for ICS commercially rated parts, are stress ratings only. Functional operation of the device at these or any other conditions above those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical parameters are guaranteed only over the recommended operating temperature range. Recommended Operation Conditions Item Rating Supply Voltage, VDD 7 V All Inputs and Outputs -0.5 V to VDD+0.5 V Ambient Operating Temperature (Commercial grade) 0 to +70 °C Ambient Operating Temperature (Industrial grade) -40 to +85 °C Storage Temperature -65 to +150 °C Soldering Temperature 260 °C Parameter Min. Typ. Max. Units Ambient Operating Temperature -40 +85 °C Power Supply Voltage (measured in respect to GND) +3.135 +5.25 V |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |