2 / 4 page ![]() 100-264Vac POWER SUPPLY BOARD FOR DMS-30 METERS DMS-EB-AC/DC Functional Specifications (TA = +25°C) Ordering Information DMS-EB-AC/DC AC power supply board RN-DMS Resistor accessory kit for DMS-30 meters AC Supply Voltage: 100 to 264Vac @ 47-68Hz AC Supply Current @ 264Vac/60Hz 60mA, maximum Isolation 1500Vac, minimum Operating Temperature Range 0 to +60°C Storage Temperature range –25 to +75°C Humidity 0 to 95%, non-condensing Dimensions 2.02" (51.31mm)L x 0.82" (20.8mm)W x 0.60" (15.3mm)D TB1 and TB2 Wire Size and Strip Length Wire Size 16 to 22 AWG (solid or stranded) Strip Length 0.25" (6.35mm) Screw Torque 3.6 pound-inches (0.4Nm) Rated Voltage 310Vac Introduction As shipped, the DMS-EB-AC/DC is configured for use with +5V-powered DMS-30PC or DMS-30LCD 3½ digit meters using the meter’s internal reference (SG13 is closed). This configuration is the most common and works well for most simple voltage measurements. Please read all of the following technical notes and perform any required modifications before soldering the DMS-EB-AC/DC onto the host meter. Many of the applications described below apply to both DMS-30 (3½ digit resolution) and DMS-40 (4½ digit resolution) meters. However, Application 5, installing the span (R4) and offset (R5) adjust potentiometers, can only be used with DMS-30PC/LCD meters. Also note that some of the other applications require the installation of R4 and R5. See Technical Note 4 when using the DMS-EB-AC/DC with DMS-40LCD meters. !IMPORTANT! AC power must be disconnected from TB2 terminals 1 and 2 before making modifications or installing user-supplied components on the DMS-EB-AC/DC board! In many applications, the DMS-EB-AC/DC installation is subject to electrical-code requirements (for example, the NEC in the USA). Fusing, grounding, wire gauges, and leakage currents may be regulated items. Since the DMS-EB-AC/DC is a line- operated device, it presents a shock hazard and should be installed only by qualified personnel. Do not hesitate to contact DATEL if you have any questions. Technical Notes 1. Soldering and Wiring: DATEL recommends the use of “no-clean” solders when installing components or making modifications to the DMS- EB-AC/DC. Before mating the DMS-EB-AC/DC to the host meter, ensure that modifications, if any, have been correctly made and that all cut solder-gaps are fully open. Align pin 1 of the meter with pin 1 of the DMS-EB-AC/DC, slide the board down flush to the meter’s housing and solder all 12 pins. Lastly, carefully cut the meter’s 12 pins as close as possible to the pc-board surface. Making absolutely sure that the AC supply is de-energized (OFF), connect the AC supply to TB2 terminals 1 (AC LO) and 2 (AC HI). Connect the input signal being measured to TB1 terminals 1 (+HI) and 2 (-LO). 2. Grounding/Isolation: Because DMS-30 and DMS-40 meters are housed in a plastic case, a connection to AC earth ground is not required. When wired per the instructions above, the DMS-EB-AC/DC board provides a minimum of 1500V isolation between its AC supply input (TB2) and its input signal (TB1). However, please keep in mind that in many applica- tions the LO side of the input signal may be connected to AC ground (i.e., earth ground) elsewhere in the system. Any Issues pertaining to grounding and/or isolation of the DMS-EB-AC/DC power supply board must be referred to qualified technical personnel. 3. Input Resistor Dividers (See Figure 4): Use 1%, or better, metal film resistors for R1 and R2 in DMS-30 applications, and 0.5%, or better, in DMS-40LCD applications. Make sure the resistor’s power and voltage ratings are adequate for the given application. Using tight-tolerance resistors in input scaling circuits allows most calibration adjustments to be made with the meter’s internal rear-mounted potentiometers, through the access holes provided (see Technical Note 5 below). 4. DMS-40LCD Meters: The RN-DMS resistor accessory kit, comprised of potentiometers R4 (Gain/Span) and R5 (Offset/Zero), cannot be used with DMS-40LCD Series meters. However, to change the input range on DMS-40LCD meters from the default low-range (i.e., with pin 2 of the meter open) to the high range, short pin 2 to pin 1 (+5V) on the top right side of DMS-EB-AC/DC board (refer to Figure 2 and the DMS-40LCD data sheet for more information). 5. Calibration Potentiometer Adjustment Holes: Two overlapping holes on the DMS-EB-AC/DC provide access to the built-in ¾-turn calibration potentiometer on DMS-30 meters or the 3-turn potentiometer on DMS- 40LCD meters. The adjustment range of both pots is very narrow. See the applicable product data sheet for more information on each meter’s calibration potentiometers. 6. Solder Gap Identification (See Figure 2): Each solder gap’s respective number is printed directly on the pc-board surface in copper etch. Be sure to double check all solder gap modifications before applying ac power and the input signal to the DMS-EB-AC/DC. 7. AC Supply Transients: The DMS-EB-AC/DC can withstand transients typically found in instrumentation environments. Installations which contain ac-powered equipment capable of generating large voltage and/or current surges should use external energy-clamping devices. A 1500 Watt bi-directional transzorb with a minimum stand-off voltage rating that matches the highest line-voltage peaks will provide additional protection under severe fault conditions. If a transzorb or other energy limiting device is used, the ac supply feeding the DMS-EB-AC/DC should have its own fuse. Refer to the fusing section for more information. 8. AC Supply Fusing: The DMS-EB-AC/DC board does not have an internal fusing device. If required, a 0.2A slow-acting fuse is recom- mended. Be sure the fuse is rated for the applied line voltage. 2 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |