| 数据搜索系统,热门电子元器件搜索 |
|
MAX5943BEEE 数据表(PDF) 4 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX5943BEEE 数据表(HTML) 4 Page - Maxim Integrated Products |
|
4 / 20 page ![]() FireWire Current Limiter and Low-Drop ORing Switch Controller 4 _______________________________________________________________________________________ ELECTRICAL CHARACTERISTICS (continued) (VIN = 7.5V to 37V, GND = 0V, and TA = -40°C to +85°C, unless otherwise noted. Typical values are at VIN = 12V, TA = +25°C.) (Note 1) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS TIM = IN or TIM ≥ 3.4V 0.45 0.51 0.57 ms RTIM = 4kΩ 27 32.5 38 µs RTIM = 50kΩ 228 345 403 µs Circuit-breaker mode, MAX5943B TIM = floating 3.75 5.5 7 ms TIM = IN or TIM ≥ 3.4V 0.89 1.00 1.13 ms RTIM = 4kΩ 54 65 76 µs RTIM = 50kΩ 575 690 806 µs Circuit-breaker mode, MAX5943C TIM = floating 7.5 10.9 14 ms TIM = IN 1.78 2.02 2.26 ms RTIM = 4kΩ 109 130 151 µs RTIM = 50kΩ 1.15 1.38 1.61 ms Circuit-breaker mode, MAX5943D TIM = floating 15 21.9 28 ms TIM = IN or TIM ≥ 3.4V 3.56 4.05 4.52 ms RTIM = 4kΩ 217 260 303 µs RTIM = 50kΩ 2.3 2.76 3.23 ms Circuit-Breaker Timeout (MAX5943B–MAX5943E) (Note 7) tCB Circuit-breaker mode, MAX5943E TIM = floating 30 44 56 ms Automatic Restart Delay After Current-Limit/Circuit-Breaker Timeout tOFF LATCH = GND (Note 8) 128 x (tILIM OR tCB) ms GATE1 Turn-Off Time (ORing Response Time) tOR From VOR trigger until (VGATE1 - VIN) < 1V, CGATE1 = 10nF 100 ns Turn-Off Response Time tON_OFF Time from VON < (VON_OFF - Hysteresis) until (VGATE2 - VOUT) < 1V, GATE2 = open (Note 9) 0.34 0.6 µs Minimum Delay from ON Low to Low-Current Shutdown Mode tSD ON step from 1.3V to 0.4V 50 µs Note 1: All min/max parameters are tested at +25°C and +85°C. Limits at -40°C are guaranteed by design. Note 2: Measured at both VGATE2 = VOUT = 0V and VGATE2 = VOUT = VIN. Note 3: The typical value of parameter VTHF is 1.5 x VTH. Note 4: Current-Limit/Circuit-Breaker Timeout; IN or ON low. Note 5: See the Typical Operating Circuit. Measured at VGATE1 = VSENSE. Note 6: The tristate (“floating”) logic condition will be entered if the pin current is within these limits. Note 7: RTIM is connected from TIM to GND. The maximum timeout period is enforced to prevent arbitrarily long operation in cur- rent-limit mode. Therefore, the relationship between resistor value and timeout changes for large values of RTIM. See Current-Limit Timeout vs. RTIM in the Typical Operating Characteristics for nominal values. Note 8: Parameter tOFF is a direct multiple of tILIM (or tCB), so the limits for tOFF track the limits for tILIM (or tCB). Note 9: If the ON voltage goes below VON_REF - Hysteresis, then GATE2 goes low immediately to disconnect power from the load quickly (within tON_OFF). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |