| 数据搜索系统,热门电子元器件搜索 |
|
MPXM2202GS 数据表(PDF) 28 Page - Motorola, Inc |
|
|
|||||||||||||||||||||||||||||
MPXM2202GS 数据表(HTML) 28 Page - Motorola, Inc |
|
28 / 670 page ![]() 1–22 Motorola Sensor Device Data www.motorola.com/semiconductors Figure 5. Experimental results for the etching of (100) silicon with approximately 5x10–5 cm–3 boron doping density in a commercially available detergent as a function of temperature and detergent concentration (which is proportional to pH). Etch Rate <= 0.10 <= 0.20 <= 0.30 Prediction <= 0.40 > 0.40 from Model 10 0 60 70 80 90 100 110 120 20 30 40 50 Contour Plot of Detergent Concentraion and Temperature vs Etch Rate ( m/hr) m ULTRA TIDE CONC (g/l) Polymer Swelling or Dissolution Swelling or dissolution affects those polymers typically employed to package the micromachined structure and depending on the nature of the media, may have a degrading effect on device performance. These two related phenomena are caused by solvent diffusing into the material and occupying free volume within the polymer. The solubility parameter gives a quantitative measure of the potential for swelling [21]: i.e., it provides a quantitative measure of “like dissolves like” (Fig. 6). Both the polymer and the solution contribute to this failure mechanism, while the media (specifically, the solubility parameter), the temperature, and the pressure can be used as acceleration factors. Figure 6. Typical values of solubility parameter ( δ [cal/cm3]1/2) for solvents and polymers. ISOOCTANE TOLUENE ETHANOL METHANOL WATER 22.5 20 17.5 15 12.5 10 7.5 Solvents POLYSULFONE POLYURETHANE PET NYLON POLY (ACRYLONITRILE) Polymers PTFE PMMA δ = [cal/cm3]1/2 Figure 7 shows a photograph of a device after exposure to a harsh fuel containing corrosive water solution. This corrosion and evidence of swelling of the gel demonstrates the vital importance the package has on the reliability of the pressure sensor device. Also, it has been observed that corrosion occurs more readily following swelling of a polymeric encapsulant. Figure 7. Photograph of a pressure sensor device after extended exposure to harsh fuel containing corrosive water, followed by exposure to a strong acid. Evidence of the gel swelling during the test, and corresponding shrinkage after removal from the test media can be seen by the gel retracting away from the sidewall of the package. INITIAL EDGE OF GEL GEL EDGE AFTER EXPOSURE TO GASOLINE WITH ETHANOL Freescale Semiconductor, Inc. For More Information On This Product, Go to: www.freescale.com |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |