Back Button LSGT77K Datasheet HTML 8Page - OSRAM GmbH LSGT77K Datasheet HTML 9Page - OSRAM GmbH LSGT77K Datasheet HTML 10Page - OSRAM GmbH LSGT77K Datasheet HTML 11Page - OSRAM GmbH LSGT77K Datasheet HTML 12Page - OSRAM GmbH LSGT77K Datasheet HTML 13Page - OSRAM GmbH LSGT77K Datasheet HTML 14Page - OSRAM GmbH LSGT77K Datasheet HTML 15Page - OSRAM GmbH LSGT77K Datasheet HTML 16Page - OSRAM GmbH  
Zoom Inzoom in Zoom Outzoom out
 16 / 16 page
background image
LSG T77K
2012-04-20
16
Fußnoten:
1)
Helligkeitswerte werden während eines Strompulses einer
typischen
Dauer
von
25
ms,
mit
einer
internen
Reproduzierbarkeit von +/- 8 % und einer erweiterten
Messunsicherheit von +/- 11 % gemessen (gemäß GUM
mit Erweiterungsfaktor k = 3).
2)
Die LED kann kurzzeitig in Sperrichtung betrieben werden.
3)
R
thJA
ergibt sich bei Montage auf PC-Board FR 4
(Padgröße
≥ 16 mm2 je Pad)
4)
Die
dominante
Wellenlänge
wird
während
eines
Strompulses einer typischen Dauer von 25 ms, mit einer
internen Reproduzierbarkeit von +/- 0,5 nm und einer
erweiterten Messunsicherheit von +/- 1 nm gemessen
(gemäß GUM mit Erweiterungsfaktor k = 3).
5)
Vorwärtsspannungen werden während eines Strompulses
einer typischen Dauer von 8 ms, mit einer internen
Reproduzierbarkeit von +/- 0,05 V und einer erweiterten
Messunsicherheit von +/- 0,1 V gemessen (gemäß GUM
mit Erweiterungsfaktor k=3).
6)
Wegen der besonderen Prozessbedingungen bei der
Herstellung von LED können typische oder abgeleitete
technische Parameter nur aufgrund statistischer Werte
wiedergegeben
werden.
Diese
stimmen
nicht
notwendigerweise
mit
den
Werten
jedes
einzelnen
Produktes überein, dessen Werte sich von typischen und
abgeleiteten
Werten
oder
typischen
Kennlinien
unterscheiden können. Falls erforderlich, z.B. aufgrund
technischer Verbesserungen, werden diese typischen
Werte ohne weitere Ankündigung geändert.
7)
Im gestrichelten Bereich der Kennlinien muss mit erhöhten
Helligkeitsunterschieden
zwischen
Leuchtdioden
innerhalb einer Verpackungseinheit gerechnet werden.
Dimmverhältnis im Gleichstrom-Betrieb max. 5:1 für
amber
8)
Maße werden wie folgt angegeben: mm (inch)
9)
Gehäuse hält TTW-Löthitze aus
10) Ein
kritisches
Bauteil
ist
ein
Bauteil,
das
in
lebenserhaltenden Apparaten oder Systemen eingesetzt
wird
und
dessen
Defekt
voraussichtlich
zu
einer
Fehlfunktion dieses lebenserhaltenden Apparates oder
Systems führen wird oder die Sicherheit oder Effektivität
dieses Apparates oder Systems beeinträchtigt.
11) Lebenserhaltende Apparate oder Systeme sind für
(a) die Implantierung in den menschlichen Körper
oder
(b) für die Lebenserhaltung bestimmt.
Falls sie versagen, kann davon ausgegangen werden,
dass die Gesundheit und das Leben des Patienten in
Gefahr ist.
Published by
OSRAM Opto Semiconductors GmbH
Leibnizstraße 4, D-93055 Regensburg
www.osram-os.com
© All Rights Reserved.
Remarks:
1)
Brightness values are measured during a current pulse of
typical 25 ms, with an internal reproducibility of +/- 8 % and
an expanded uncertainty of +/- 11 % (acc. to GUM with a
coverage factor of k = 3).
2)
Driving the LED in reverse direction is suitable for short
term application.
3)
R
thJA
results
from
mounting
on
PC
board
FR 4
(pad size
≥ 16 mm2 per pad)
4)
The dominant wavelength is measured at a current pulse
of typical 25 ms, with an internal reproducibility of +/- 0,5
nm and an expanded uncertainty of +/- 1 nm (acc. to GUM
with a coverage factor of k=3).
5)
The forward voltage is measured during a current
pulse of typical 8 ms, with an internal reproducibility of
+/- 0,05 V and an expanded uncertainty of +/- 0,1 V
(acc. to GUM with a coverage factor of k=3).
6)
Due to the special conditions of the manufacturing
processes
of LED, the typical data or calculated
correlations of technical parameters can only reflect
statistical figures. These do not necessarily correspond to
the actual parameters of each single product, which could
differ from the typical data and calculated correlations or
the typical characteristic line. If requested, e.g. because of
technical improvements, these typ. data will be changed
without any further notice.
7)
In the range where the line of the graph is broken, you
must expect higher brightness differences between single
LEDs within one packing unit.
Dimming range for direct current mode max. 5:1 for amber
8)
Dimensions are specified as follows: mm (inch)
9)
Package able to withstand TTW-soldering heat
10) A critical component is a component used in a life-support
device or system whose failure can reasonably be
expected to cause the failure of that life-support device or
system, or to affect its safety or the effectiveness of that
device or system.
11) Life support devices or systems are intended
(a) to be implanted in the human body,
or
(b) to support and/or maintain and sustain human life. If
they fail, it is reasonable to assume that the health and the
life of the user may be endangered.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com