| 数据搜索系统,热门电子元器件搜索 |
|
RPA200H-RUW 数据表(PDF) 4 Page - Recom International Power |
|
|
|||||||||||||||||||||||||||||
RPA200H-RUW 数据表(HTML) 4 Page - Recom International Power |
|
4 / 10 page ![]() EXTERNAL CAPACITOR REMOTE ON/OFF REMOTE SENSE PB-4 REV.: 0/2017 www.recom-power.com DC/DC Converter Specifications (measured @ ta = 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RPA200H-RUW Series Trim down RPA200H series Trim down 1 2 3 4 5 6 7 8 9 10 % R 2 = 499 243 162 118 90.9 75 63.4 53.6 46.4 41.2 kOhms Trim down 11 12 13 14 15 16 17 18 19 20 % R 2 = 36.5 32.4 28.7 26.1 23.7 22.1 20 18.2 16.5 15.4 kOhms +Vout +Vin -Vin -Vout (GND) +Sense RW1 RW2 R1 R2 -Sense Trim R1 -Vin +Vin +Vout -Vout CTRL C1 Q1 R1 Ext. Cap. +Vout -Vout -Vin Hold Up Circuit D1 C1 C2 +Vin +Vout -Vout UVLO -Vin R1 R1 -Vin +Vin +Vout -Vout CTRL C1 Q1 R1 Ext. Cap. +Vout -Vout -Vin Hold Up Circuit D1 C1 C2 +Vin +Vout -Vout UVLO -Vin R1 RW1 ... wire losses + RW2 ... wire losses - R1 ... trim up resistor R2 ... trim down resistor RPA200H-11024SRUW Trim up 1 2 3 4 5 6 7 8 9 10 % Vout = 24.24 24.48 24.72 24.96 25.20 25.44 25.68 25.92 26.16 26.40 Volts R 1 = 9530 4870 3240 2490 2000 1690 1430 1270 1150 1050 kOhms RPA200H-11012SRUW Trim up 1 2 3 4 5 6 7 8 9 10 % Vout = 12.12 12.24 12.36 12.48 12.60 12.72 12.84 12.96 13.08 13.20 Volts R 1 = 4530 2320 1540 1150 931 787 681 604 536 487 kOhms Trim up: A 240µF/200V capacitor (C2) is required for normal operation. To meet power supply interruptions, an external circuit comprised of a capacitor (C1), a 100R 10W resistor (R1) and a FX2000D diode (D1) is required. C1 24Vin 36Vin 48Vin 72Vin 96Vin 110Vin For 10ms 2300µF 2300µF 2300µF 2300µF 1200µF 800µF For 30ms 6900µF 6900µF 6900µF 6900µF 3600µF 2400µF The output voltage can be adjusted by both trim and remote sense. The maximum combined adjustment range is ±10%. Derate the maximum output power if using the trim or sense function to increase the output voltage. Remote on/off can be controlled by an external voltage or transistor between the CTRL terminal and the Vin(-) terminal. For negative logic if the remote on/off feature is not used, short the on/off pin to Vin(-). For positive logic if the remote on/off feature is not used, leave the on/off pin floating. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |