| 数据搜索系统,热门电子元器件搜索 |
|
GL652USB 数据表(PDF) 10 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
GL652USB 数据表(HTML) 10 Page - List of Unclassifed Manufacturers |
|
10 / 17 page ![]() 10 08/18/00 GL652USB 7 PORT USB HUB CONTROLLER Revision 1.2 Host command to the hub: PT_CMD3~0 : 4’h0 –SetPortFeature(PORT_SUSPEND) : 4’h1 –SetPortFeature(PORT_RESET) : 4’h2 –SetPortFeature(PORT_POWER) : 4’h3 –ClearPortFeature(PORT_ENABLE) : 4’h4 –ClearPortFeature(PORT_SUSPEND) : 4’h5 –ClearPortFeature(PORT_POWER) : 4’h6 –ClearPortFeature(C_PORT_RESET) : 4’h7 –ClearPortFeature(C_PORT_OVER_CURRENT) : 4’h8 –ClearPortFeature(C_PORT_SUSPEND) : 4’h9 –ClearPortFeature(C_PORT_ENABLE) : 4’hA –ClearPortFeature(C_PORT_CONNECTION) HB_CMD3 : 1’b1 –SetHubFeature(C_HUB_LOCAL_POWER) HB_CMD2 : 1’b1 –SetHubFeature(C_HUB_OVER_CURRENT) HB_CMD1 : 1’b1 –ClearHubFeature(C_HUB_LOCAL_POWER) HB_CMD0 : 1’b1 –ClearHubFeature(C_HUB_OVER_CURRENT) ENP1_IND ( offset 0C, default = 00h ) R/O R/O R/O R/O R/O R/O R/O R/O PT7 PT6 PT5 PT4 PT3 PT2 PT1 HUB Endpoint 1 interrupt change indicator TRXFLAG ( offset 0D, default = 00h ) R/W1C R/W1C R/W1C R/W1C R/W1C R/W1C R/W1C -- P7_TRX P6_TRX P5_TRX P4_TRX P3_TRX P2_TRX P1_TRX Upstream traffic flag: P1_TRX : upstream traffic happens on downstream port 1 P2_TRX : upstream traffic happens on downstream port 2 P3_TRX : upstream traffic happens on downstream port 3 P4_TRX : upstream traffic happens on downstream port 4 P5_TRX : upstream traffic happens on downstream port 5 P6_TRX : upstream traffic happens on downstream port 6 P7_TRX : upstream traffic happens on downstream port 7 LED_INIT ( offset 0E, default = 00h ) R/W1C R/W1C R/W1C R/W1C R/W1C R/W1C R/W1C -- P7_ON P6_ON P5_ON P4_ON P3_ON P2_ON P1_ON LED initial flag: P1_ON : if 1’b1, LED is always on, otherwise, judge according to TRXFLAG register. P2_ON : if 1’b1, LED is always on, otherwise, judge according to TRXFLAG register. P3_ON : if 1’b1, LED is always on, otherwise, judge according to TRXFLAG register. P4_ON : if 1’b1, LED is always on, otherwise, judge according to TRXFLAG register. P5_ON : if 1’b1, LED is always on, otherwise, judge according to TRXFLAG register. P6_ON : if 1’b1, LED is always on, otherwise, judge according to TRXFLAG register. P7_ON : if 1’b1, LED is always on, otherwise, judge according to TRXFLAG register. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |