| 数据搜索系统,热门电子元器件搜索 |
|
CP10.241-R2 数据表(PDF) 18 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP10.241-R2 数据表(HTML) 18 Page - PULS GmbH |
|
18 / 31 page ![]() CP10.241-R1, CP10.241-R2, CP10.241-R3,CP10.242-R2 CP-Series 24V, 10A, 240W, SINGLE PHASE Feb. 2018 / CP10.241-R2 Rev0.3-EN - All values are typical figures specified at 230Vac, 50Hz input voltage, 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 18/31 P R E L I M I N A R Y 17. ENVIRONMENT Operational temperature -25°C to +70°C (-13°F to 158°F) Operational temperature is the same as the ambient or surrounding temperature and is defined as the air temperature 2cm below the unit. Storage temperature -40°C to +85°C (-40°F to 185°F) For storage and transportation Output de-rating 1) 0.13A/°C 0.25A/°C 0.63A/1000m or 5°C/1000m 0.38A/-5kPa or 3°C/-5kPa Between +45°C and +60°C (113°F to 140°F) Between +60°C and +70°C (140°F to 158°F) For altitudes >2000m (6560ft), see Fig. 17-2 For atmospheric pressures <80kPa, see Fig. 17-2 Humidity 5 to 95% r.h. According to IEC 60068-2-30 Do not energize while condensation is present. Atmospheric pressure 110-47kPa See see Fig. 17-2 for details Altitude Up to 6000m (20 000ft) See see Fig. 17-2 for details Over-voltage category III According to IEC 60664-1 for altitudes up to 2000m II According to IEC 60664-1, for altitudes between 2000 and 6000m and atmospheric pressures from 80-47kPa. Degree of pollution 2 According to IEC 60664-1, not conductive Vibration sinusoidal 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g 2 hours / axis According to IEC 60068-2-6 Shock 2) 30g 6ms, 20g 11ms 3 bumps per direction, 18 bumps in total According to IEC 60068-2-27 LABS compatibility As a rule, only non-silicon precipitating materials are used. The unit conforms to the LABS criteria and is suitable for use in paint shops. Corrosive gases Tested according to ISA-71.04-1985, Severity Level G3 and IEC 60068-2-60 Test Ke Method 4 for a service life of minimum 10years in these environments. Audible noise Some audible noise may be emitted from the power supply during no load, overload or short circuit. 1) The de-rating is not hardware controlled. The customer has to take this into consideration to stay below the de-rated current limits in order not to overload the unit. 2) Shock and vibration is tested in combination with DIN-Rails according to EN 60715 with a height of 15mm and a thickness of 1.3mm and standard orientation. Fig. 17-1 Output current vs. ambient temp. Fig. 17-2 Output current vs. altitude Allowed Output Current 0 -25 0 20 40 70°C 2A 4A 6A 8A 10A 12A 60 A B A... continuous B... short term (max. 5s) 2000m 4000m 6000m 2A 4A 6A 8A 10A 12A Altitude Allowed Output Current B C A... Tamb < 60°C B... Tamb < 50°C C... Tamb < 45°C D... Short term A D AP*) 80kPa 62kPa 47kPa 110kPa 0m Ambient Temperature *) Atmospheric pressure |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |