| 数据搜索系统,热门电子元器件搜索 |
|
CP10.241-R2 数据表(PDF) 25 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP10.241-R2 数据表(HTML) 25 Page - PULS GmbH |
|
25 / 31 page ![]() CP10.241-R1, CP10.241-R2, CP10.241-R3,CP10.242-R2 CP-Series 24V, 10A, 240W, SINGLE PHASE Feb. 2018 / CP10.241-R2 Rev0.3-EN - All values are typical figures specified at 230Vac, 50Hz input voltage, 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 25/31 P R E L I M I N A R Y 24. APPLICATION NOTES 24.1. PEAK CURRENT CAPABILITY The unit can deliver peak currents (up to several milliseconds) which are higher than the specified short term currents. This helps to start current demanding loads. Solenoids, contactors and pneumatic modules often have a steady state coil and a pick-up coil. The inrush current demand of the pick-up coil is several times higher than the steady-state current and usually exceeds the nominal output current. The same situation applies when starting a capacitive load. The peak current capability also ensures the safe operation of subsequent circuit breakers of load circuits. The load branches are often individually protected with circuit breakers or fuses. In case of a short or an overload in one branch circuit, the fuse or circuit breaker need a certain amount of over-current to open in a timely manner. This avoids voltage loss in adjacent circuits. The extra current (peak current) is supplied by the power converter and the built-in large sized output capacitors of the power supply. The capacitors get discharged during such an event, which causes a voltage dip on the output. The following two examples show typical voltage dips for a resistive load: Fig. 24-1 20A peak current for 50ms , typ. (2x the nominal current) Fig. 24-2 50A peak current for 5ms , typ. (5x the nominal current) Output Voltage 24V Output Voltage 24V 10ms/DIV Output Current 0A 20A 17V Output Current 1ms/DIV 0A 50A 15.5V Fig. 24-3 30A peak current for 12ms , typ. (3x the nominal current) 24V 10ms/DIV Output Voltage Output Current 0A 12ms 30A 10.5V Please note: The DC-OK relay triggers when the voltage dips more than 10% for longer than 1ms. Peak current voltage dips Typically from 24V to 17V At 20A for 50ms, resistive load Typically from 24V to 19V At 50A for 2ms, resistive load Typically from 24V to 15.5V At 50A for 5ms, resistive load |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |