| 数据搜索系统,热门电子元器件搜索 |
|
CP10.241-R3 数据表(PDF) 12 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP10.241-R3 数据表(HTML) 12 Page - PULS GmbH |
|
12 / 31 page ![]() CP10.241-R1, CP10.241-R2, CP10.241-R3,CP10.242-R2 CP-Series 24V, 10A, 240W, SINGLE PHASE Feb. 2018 / CP10.241-R2 Rev0.3-EN - All values are typical figures specified at 230Vac, 50Hz input voltage, 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 12/31 P R E L I M I N A R Y 10. LIFETIME EXPECTANCY The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years (131 400h). Any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices. AC 100V AC 120V AC 230V Lifetime expectancy 143 000h 153 000h 188 000h At 5A and 40°C 405 000h 434 000h 531 000h At 5A and 25°C 66 000h 78 000h 109 000h At 10A and 40°C 188 000h 220 000h 307 000h At 10A and 25°C 37 000h 47 000h 71 000h At 12A and 40°C 105 000h 132 000h 200 000h At 12A and 25°C 11. MTBF MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product. The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it can not be determined if the failed unit has been running for 50 000h or only for 100h. For these types of units the MTTF (Mean Time To Failure) value is the same value as the MTBF value. AC 100V AC 120V AC 230V MTBF SN 29500, IEC 61709 535 000h 556 000h 641 000h At 10A and 40°C 972 000h 1 006 000h 1 138 000h At 10A and 25°C MTBF MIL HDBK 217F 205 000h 208 000h 232 000h At 10A and 40°C; Ground Benign GB40 279 000h 283 000h 318 000h At 10A and 25°C; Ground Benign GB25 45 000h 46 000h 53 000h At 10A and 40°C; Ground Fixed GF40 58 000h 59 000h 63 000h At 10A and 25°C; Ground Fixed GF25 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |