| 数据搜索系统,热门电子元器件搜索 |
|
ZL6100ALAF 数据表(PDF) 21 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
ZL6100ALAF 数据表(HTML) 21 Page - Renesas Technology Corp |
|
21 / 34 page ![]() ZL6100 FN6876 Rev 3.00 Page 21 of 34 August 29, 2012 The blanking time represents the time when no current measurement is taken. This is to avoid taking a reading just after a current load step (less accurate due to potential ringing). It is a configurable parameter. Table 15 includes default parameters for the number of violations and the blanking time using pin-strap. Once the sensing method has been selected, the user must select the voltage threshold (VLIM), the desired current limit threshold, and the resistance of the sensing element. The current limit threshold can be selected by simply connecting the ILIM0 and ILIM1 pins as shown in Table 17. The ground- referenced sensing method is being used in this mode. The threshold voltage can also be selected in 5mV increments by connecting a resistor, RLIM0, between the ILIM0 pin and ground according to Table 18. This method is preferred if the user does not desire to use or does not have access to the I2C/SMBus interface and the desired threshold value is contained in Table 18. The current limit threshold can also be set to a custom value via the I2C/SMBus interface. Please refer to Application Note AN2033 for further details. TABLE 16. RESISTOR CONFIGURED CURRENT SENSING METHOD SELECTION RILIMI1 (k ) CURRENT SENSING METHOD NUMBER OF VIOLATIONS ALLOWED (Note 25) 10 Ground-referenced, rDS(ON), sensing Best for low duty cycle and low fSW Blanking time: 672ns 1 11 3 12.1 5 13.3 7 14.7 9 16.2 11 17.8 13 19.6 15 21.5 Output-referenced, down-slope sensing (Inductor DCR sensing) Best for low duty cycle and high fSW Blanking time: 352ns 1 23.7 3 26.1 5 28.7 7 31.6 9 34.8 11 38.3 13 42.2 15 46.4 Output-referenced, up-slope sensing (Inductor DCR sensing) Best for high duty cycle Blanking time: 352ns 1 51.1 3 56.2 5 61.9 7 68.1 9 75 11 82.5 13 90.9 15 NOTE: 25. The number of violations allowed prior to issuing a fault response TABLE 17. CURRENT LIMIT THRESHOLD VOLTAGE PIN-STRAP SETTINGS ILIM0 LOW (mV) OPEN (mV) HIGH (mV) LOW 20 30 40 ILIM1 OPEN 50 60 70 HIGH 80 90 100 TABLE 18. CURRENT LIMIT THRESHOLD VOLTAGE RESISTOR SETTINGS RILIM0 (k ) VLIM for RDS (mV) VLIM for DCR (mV) 10 0 0 11 5 2.5 12.1 10 5 13.3 15 7.5 14.7 20 10 16.2 25 12.5 17.8 30 15 19.6 35 17.5 21.5 40 20 23.7 45 22.5 26.1 50 25 28.7 55 27.5 31.6 60 30 34.8 65 32.5 38.3 70 35 46.4 80 40 51.1 85 42.5 56.2 90 45 68.1 100 50 82.5 110 55 100 120 60 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |