10 / 18 page ![]() L9848 10/18 the fault data bits out on the DO pin. CS has an integrated glitch filter for spurious pulses of 50ns or shorter (i.e. no fault data and Outputs1-8 enable status will be altered). For open circuit condition the CS is internally pulled down to GND. – Serial Clock (SCLK) This is the clock signal input for synchronization of serial data transfer. DI data is shifted into the DI input on the rising edge of SCLK and DO data changes on the falling edge of SCLK. SPI DI Input Command Register An input byte (8bits) is routed to the Command Register. The content of this Command Register is given in Table 1 and Table 2. Additional DI data will continue to be wrapped around to the DO pin. If CS will go low before a complete reception of the current byte, this just transmitted byte will be ignored Table 1. Bit Command Register Definition Table 2. Command Register Logic Definition Fault Operation The fault diagnostic capability consists of one internal 8bit shift register. Open or shorted load detection is pro- vided by comparing the source or drain voltage with the VDD voltage. When an output connected as either a low side device or a high side device is commanded OFF, an open load can be detected. When an output con- nected as either a low side device or a high side device is commanded ON a shorted load can be detected. The fault bit is "set" for each channel if a short, open, or over-temperature condition occurs for Outputs1-8. The con- tent of this Fault Register is given in Table 3. The output load status of each individual channel is defined in Table 4. Open and shorts are subsequently re-latched provided they meet the minimum duration criterion and thermal faults will be re-latched provided they meet the duration criterion after CS goes "LOW", if these fault conditions are still present. The fault register is capable of detecting and latching multiple fault conditions (among the 8 outputs) that have occurred between clearing of the fault flags. All of the faults will be cleared on the falling edge of Chip Select (CS). Table 3. Fault Register Definition Table 4. Fault Logic Definition MSB LSB OUT8 OUT7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 D07 D06 D05 D04 D03 D02 D01 D00 BIT STATE STATUS D00-D07 0 OUTPUT1-8 are commanded OFF D00-D07 1 OUTPUT1-8 are commanded ON MSB LSB Fault8 Fault7 Fault6 Fault5 Fault4 Fault3 Fault2 Fault1 D07 D06 D05 D04 D03 D02 D01 D00 BIT STATE STATUS Fault1-8 0 OUT1-8 are not open or shorted (nominal) Fault1-8 1 OUT1-8 are either open or shorted or in thermal shutdown |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |