| 数据搜索系统,热门电子元器件搜索 |
|
E32-R16 数据表(PDF) 107 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E32-R16 数据表(HTML) 107 Page - Omron Electronics LLC |
|
107 / 108 page ![]() E32 E32 108 J INSTALLING FIBER CABLES Bends in Fiber cables Plastic and glass filament fiber cables may be bent to avoid obstacles on the way to the sensing site. Here are some guidelines about the location of cable bends: The first bend must be as least 20 mm (0.79 in) away from where the cables enter the amplifier. The last bend must be at least 20 mm (0.79 in) bending the sensing head. We recommend a 25 mm (1.0 in) minimum radius for a right angle bend to maintain the rated sensing distance. The sharpest allowable right angle bend is over a 10 mm (0.39 in) radius, but this will result in a shorter sensing distance. Refer to the bending radius graph. Amplifier Fiber unit 40 mm max. 20 mm max. Correct Incorrect Do not apply excess force on the Fiber Units. Do not pull or press the Fiber Units. The Fiber Units have a withstand force of 1 kg or 3 kg (pay utmost attention because the fibers are thin). Do not bend the Fiber Units beyond the permissible bending radius. Do not bend the edge of the Fiber Units. Bending radius [mm (inch)] Bending radius (0.197) (0.394) (0.591) (0.787) (0.984) (1.181) E3S1-- X3 amplifier with E32-DC200 diffuse reflective fiber cable Proper Supports for Cables To support the fiber cable between the sensing site and the amplifier, mount the cable using a nylon strap or cable tie. Do not use a U-shaped strap that will compress or put stress on the fiber cable. To prevent damage from excessive vibration, take up the fiber in a loop as shown below. Fiber unit Nylon wireholder Correct Incorrect Metal holder The Fiber Head could be broken by excessive vibration. To prevent this, the following is effective: A one-turn loop can absorb vibrations. Tape J LONGER FIBER-OPTIC CABLES Applicable Models E32-TC200/-DC200 E32-TC200B/-DC200B E32-TC200E/-DC200E E32-TC200F/-DC200F E32-TC200A Appearance The length can be ordered in increments of 1 m between 6 m min. and 20 m max. (2-m and 5-m fiber length types are standard for E32-TC200, E32-DC200.) ℓ E39-F10 Fiber Connector Use the following procedure (refer to the figure) to connect fibers via the Fiber Connector. Splice Retention Unit Retention Unit Each fiber should be as close as possible before they are connected. Sensing distance will be reduced by approximately 25% when fibers are connected. Only fibers with 2.2 mm dia. can be connected. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |