13 / 34 page ![]() Si5321 Rev. 2.3 13 Wander/Jitter at 6400 Hz Bandwidth (BWSEL[1:0] = 11 and BWBOOST = 0) Jitter Tolerance (see Figure 7) JTOL(PP) f= 64 Hz 1000 — —ns f= 640Hz 100 — —ns f = 6400 Hz 10 — —ns CLKOUT RMS Jitter Generation FEC[2:0] = 000 JGEN(RMS) 12 kHz to 20 MHz — 1.0 1.3 ps 50 kHz to 80 MHz — 0.4 .55 ps CLKOUT RMS Jitter Generation FEC[2:0] = 001, 010, 100,101, 110, 111 JGEN(RMS) 12 kHz to 20 MHz — 1.0 1.5 ps 50 kHz to 80 MHz — .45 0.7 ps CLKOUT Peak-Peak Jitter Generation FEC[2:0] = 000 JGEN(PP) 12 kHz to 20 MHz — 9.3 13.0 ps 50 kHz to 80 MHz — 4.1 6.0 ps CLKOUT Peak-Peak Jitter Generation FEC[2:0] = 001, 010, 100,101, 110, 111 JGEN(PP) 12 kHz to 20 MHz — 8.0 20.0 ps 50 kHz to 80 MHz — 4.0 7.5 ps Jitter Transfer Bandwidth (see Figure 6) FBW BW = 6400 Hz — 6400 —Hz Wander/Jitter Transfer Peaking JP < 6400 Hz — 0.05 0.1 dB Wander/Jitter at 12800 Hz Bandwidth (BWSEL[1:0] = 11 and BWBOOST = 1) Jitter Tolerance (see Figure 7) f = 128 Hz 500 — — ns f = 1280 Hz 50 — — ns f = 12800 Hz 5 — — ns CLKOUT RMS Jitter Generation FEC[2:0] = 000 JGEN(RMS) 12 kHz to 20 MHz — .85 1.2 ps 50 kHz to 80 MHz — .35 .55 ps CLKOUT Peak-Peak Jitter Generation FEC[2:0] = 000 JGEN(PP) 12 kHz to 20 MHz — 6.8 11.0 ps 50 kHz to 80 MHz — 3.4 5.5 ps Jitter Transfer Bandwidth (see Figure 6) FBW BW = 12,800 Hz — 12800 — Hz Wander/Jitter Transfer Peaking JP < 12,800 Hz — 0.05 .1 dB Acquisition Time TAQ RSTN/CAL high to CAL_ACTV low, with valid clock input and VALTIME = 0 — 300 350 ms Table 4. AC Characteristics (PLL Performance Characteristics) (Continued) (VDD33 =3.3 V ±5%, TA =–20 to 85 °C) Parameter Symbol Test Condition Min Typ Max Unit Notes: 1. Higher PLL bandwidth settings provide smaller clock output wander with temperature gradient. 2. For reliable device operation, temperature gradients should be limited to 10 °C/min. 3. Telcordia GR-1244-CORE requirements specify maximum phase transient slope during clock rearrangement in terms of nanoseconds per millisecond. The equivalent ps/ µs unit is used here since the maximum phase transient magnitude for the Si5321 (tPT_MTIE) never reaches one nanosecond. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |